Parameter setting
6-5
L
BA2141 EN 1.0
Details about the
parameter data
6th byte
7th byte
8th byte
9th byte
parameter data
telegram:
Error code
If processing the order is completed correctly, the variable
nvoParamRes
contains the read data
or a copy of the written data.
If an error occurs in the network variable
nvoParamRes
the error code will be entered in byte 9.
The error code can be read from byte 9 if
•
the value of byte 1 = 1 and
•
bit 7 is set in byte 5 (i.e. the value of byte 5 = 80
hex
, see example below).
Tip!
Strings and data blocks cannot be written.
The following table explains the error codes.
Error code
dec
hex
Meaning of error message
01
01
Service-ID invalid
02
02
Caller-ID invalid
03
03
Data type invalid
04
04
Subcode-No. invalid
05
05
Code-No. invalid
06
06
Parameter invalid, general
07
07
No access authorisation because of operating status
08
08
No access authorisation because of operating mode
09
09
No access authorisation because parameter can only be read
10
A
No access authorisation
11
B
Data block too long
12
C
Collision with other parameter values
14
D
Quit value range
15
I
General limit value exceeding
32
20
General
33
21
Time limit exceeded
34
22
Frame error
35
23
Parity error
36
24
Overflow
Example:
The brake opening time, code C0196 (C4
hex
), is wrong.
Error code 14, ’Parameter value exceeds the max. permissible value’.
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
9th byte
01
00
C4
00
80
00
00
00
0E
Show/Hide Bookmarks
Summary of Contents for 2141
Page 6: ...Contents iv L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 14: ...Technical data 3 4 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 20: ...Installation 4 6 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 74: ...Parameter setting 6 52 L BA2141 EN 1 0 Show Hide Bookmarks ...
Page 76: ...Troubleshooting and fault elimination 7 2 L _ ONQN bk NKM Show Hide Bookmarks ...
Page 90: ...Appendix 8 14 L _ ONQN bk NKM Show Hide Bookmarks ...