background image

System x3100 M5

1

System x3100 M5

Lenovo Press Product Guide

The System x3100 M5 single-socket tower server is designed for small businesses and first-time server 

buyers looking for a solution to improve business efficiency. It delivers several innovative features with a 

competitive price, either in a compact mini-tower form factor, or standard tower form factor with hot-swap 

power supplies and disk drives. The System x3100 M5 provides next-generation performance in an 

innovative and compact design with flexible configuration options, built-in security, and systems 

management capabilities. It leverages the next-generation dual-core and quad-core Intel Xeon processor 

technology.

Suggested uses: Retail/kiosks, and SMBs, looking for file and printer servers, web serving, small 

business infrastructure, and virtual desktops for small workgroups.

Figure 1. The System x3100 M5 (compact mini-tower shown)

Did you know?

The System x3100 M5 server is a compact, cost-effective, single-processor tower or rack-mountable 

server that has been optimized to provide outstanding availability, manageability, and performance 

features to small-to-medium-sized businesses, retail stores, or distributed enterprises. It supports the 

Intel Xeon E3-1200 v3 “Haswell” family of processors for applications that require performance and 

stability, and Core i3, Pentium, and Celeron processors for applications that require lower cost.

The system includes features that are not typically seen in this class of system, such as standard, 

embedded RAID 0 and RAID 1, remote control capabilities even when the machine is powered off, and 

Predictive Failure Analysis (PFA) on processor and memory. Some models also support hot-swap 

redundant power supplies and hot-swap disk drives.

Summary of Contents for x3100 M5

Page 1: ...ving small business infrastructure and virtual desktops for small workgroups Figure 1 The System x3100 M5 compact mini tower shown Did you know The System x3100 M5 server is a compact cost effective single processor tower or rack mountable server that has been optimized to provide outstanding availability manageability and performance features to small to medium sized businesses retail stores or d...

Page 2: ...ur DIMM sockets Memory speeds up to 1600 MHz Four available high performance PCI Express 3 0 or 2 0 slots Up to four internal 3 5 inch simple swap or hot swap SATA II HDDs on some models offer low cost high capacity storage Up to eight internal 2 5 inch hot swap SAS SATA HDDs on some models offers maximum scalability and performance Integrated ServeRAID C100 software RAID controller supports RAID ...

Page 3: ...E3 1200 v3 family supports Industry standard Advanced Encryption Standard AES NI support for faster stronger encryption IBM Systems Director is included for proactive systems management It offers comprehensive systems management tools that help to increase up time reduce costs and improve productivity through advanced server management capabilities The Intel Execute Disable Bit function can help p...

Page 4: ... fixed power supply and simple swap drive bays or a standard tower with hot swap power supplies and hot swap drive bays Figures 2 and 3 show the front and rear of the x3100 M5 Figure 2 Front view of the System x3100 M5 compact tower and standard tower Figure 3 Rear view of the System x3100 M5 compact tower and standard tower ...

Page 5: ... M5 5 Figures 4 and 5 show the locations of key components inside the server Figure 4 Inside view of System x3100 M5 compact tower configuration Figure 5 Inside view of System x3100 M5 standard tower configuration ...

Page 6: ...nlow platform Memory DIMM slots Four DDR3 DIMM slots supporting UDIMMs RDIMMs are not supported Memory capacity Up to 32 GB with 8 GB DDR3 UDIMMs and four populated DIMM slots Memory protection ECC Disk drive bays Compact tower Up to four 3 5 simple swap bays Standard tower Up to four 3 5 hot swap bays HDDs or eight 2 5 hot swap bays HDDs or SSDs Maximum internal storage Compact tower Up to 12 TB ...

Page 7: ...d tower Disk drive bays and power supplies Systems management UEFI Integrated Management Module II IMM2 basic light path diagnostic tests Automatic Server Restart IBM Systems Director and ServerGuide Optional IMM Advanced FoD Upgrade for remote presence graphics keyboard and mouse and virtual media Video Matrox G200eR2 with 16 MB memory that is integrated into the IMM2 Maximum resolution is 1600x1...

Page 8: ... MHz ServeRAID C100 4x 3 5 SS Open 2x GbE DVD 1x 350W fixed 1 2 5457 C3x Xeon E3 1231 v3 3 4GHz 8MB 1600MHz 4C 80W 1x 4 GB 1600 MHz ServeRAID C100 4x 3 5 SS Open 2x GbE DVD 1x 300W fixed 1 2 Standard tower form factor hot swap drives and power supplies 5457 C5x Xeon E3 1231 v3 3 4GHz 8MB 1600MHz 4C 80W 1x 4 GB 1600 MHz ServeRAID H1110 4x 3 5 HS Open 2x GbE Multi burner 1x 430W hot swap 2 2 5457 F3...

Page 9: ... 1x 350W fixed 1 2 5457 EFx Xeon E3 1231 v3 3 4GHz 8MB 1600MHz 4C 80W 1x 8 GB 1600 MHz ServeRAID C100 4x 3 5 SS Open 2x GbE Multi burner 1x 350W fixed 1 2 Standard tower form factor hot swap drives and power supplies 5457 EEx Xeon E3 1220 v3 3 1GHz 8MB 1600MHz 4C 80W 1x 8 GB 1600 MHz ServeRAID H1110 8x 2 5 HS Open 2x GbE Multi burner 1x 430W hot swap 2 2 5457 EGx Xeon E3 1220 v3 3 1GHz 8MB 1600MHz...

Page 10: ... 1333MHz 2C 53W A58G Intel Pentium Processor G3240 3 1GHz 3MB 1333MHz 2C 53W A58H Intel Pentium Processor G3240T 2 7GHz 3MB 1333MHz 2C 35W A58J Intel Pentium Processor G3440 3 3GHz 3MB 1600MHz 2C 53W A3x A58F Intel Pentium Processor G3450 3 4GHz 3MB 1600MHz 2C 53W A3QT Intel Xeon Processor E3 1220 v3 3 1GHz 8MB 1600MHz 4C 80W B3x EBx ECx EDx EEx EGx EHx A4VZ Intel Xeon Processor E3 1220L v3 1 1GHz...

Page 11: ...han one DIMM then the DIMMs must be installed in a pair and both DIMMs in a pair must be identical in type and size The following table lists the memory options that are supported by the server Table 5 Memory options Part number Feature code Description Maximum supported Standard models where used 00D5012 A3QB 4GB 1x4GB 2Rx8 1 35V PC3L 12800 CL11 ECC DDR3 1600MHz LP UDIMM 4 A3x B3x C3x C5x EAx F3x...

Page 12: ...N133 A5VG 3TB 7 2K 6Gbps NL SATA 3 5 G2SS 512e HDD 4 512 byte sector drives 81Y9802 A22U 500GB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9806 A22X 1TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9810 A22W 2TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 81Y9814 A22V 3TB 7 2K 6Gbps NL SATA 3 5 G2SS HDD 4 Models of the x3100 M5 using the standard tower chassis and with hot swap 430 W power supplies support either up to ei...

Page 13: ...S HDDs 90Y8953 A2XE 500GB 7 2K 6Gbps NL SAS 2 5 SFF G2HS HDD 8 81Y9690 A1P3 1TB 7 2K 6Gbps NL SAS 2 5 SFF HS HDD 8 2 5 inch NL SATA HDDs 81Y9722 A1NX 250GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 81Y9726 A1NZ 500GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 81Y9730 A1AV 1TB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 8 2 5 inch Enterprise Value SSDs 00FN298 AS0D 240GB SATA 2 5 MLC HS Entry SSD 8 00FN327 AS0E 480GB SAT...

Page 14: ...Y6002 A3W9 4TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 4 3 5 inch NL SATA HDDs 512e Advanced Format drives 00FN113 A5VD 2TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN128 A5VF 3TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN143 A5VH 4TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN158 A5VK 5TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 00FN173 A5VM 6TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 4 3 5 inch NL SAS HDDs ...

Page 15: ... SATA ports Support for up to two virtual drives Support for virtual drive sizes greater than 2 TB Fixed stripe unit size of 64 KB Support for MegaRAID Storage Manager management software The following table lists the RAID controller and internal HBAs that are supported by the server Table 9 RAID controllers and HBAs for internal storage Part number Feature code Description Maximum supported Stand...

Page 16: ...eries Battery Kit Supported only with 512MB cache option 81Y4484 1 81Y4544 A1X2 ServeRAID M5100 Series Zero Cache RAID 5 Upgrade for System x 1 81Y4484 A1J3 ServeRAID M5100 Series 512MB Cache RAID 5 Upgrade for System x 1 81Y4487 A1J4 ServeRAID M5100 Series 512MB Flash RAID 5 Upgrade for System x 1 EKx 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade for System x 1 81Y4546 A1X3 ServeRA...

Page 17: ...re information see the list of Lenovo Press Product Guides in the RAID adapters category http lenovopress com systemx raid Internal backup units The server supports the internal tape drive options that are listed in the following table Internal tape drives are installed in a 5 25 inch HH bay A maximum of one tape drive is supported SAS tape drives require an internal SAS HBA to be installed in ser...

Page 18: ...B 16X DVD R DL 12X DVD R 16X DVD R DL 12X DVD RW 4 7 GB 12X DVD RW 12X DVD RAM 4 7 9 4 GB 6X The Half High SATA Multi Burner supports the same media and speeds for reading as HH DVD ROM In addition this drive supports the following media and speeds for writing CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed CD RW 16X DVD R 8X DVD R DL 8X DVD R 8X DVD R DL 8X DVD RW 6X DVD RW 8X DVD RAM 3X I O e...

Page 19: ...apter for System x 2 90Y9352 A2V3 Broadcom NetXtreme I Quad Port GbE Adapter for System x 3 49Y4230 5767 Intel Ethernet Dual Port Server Adapter I340 T2 for System x 3 49Y4240 5768 Intel Ethernet Quad Port Server Adapter I340 T4 for System x 3 00AG500 A56K Intel I350 F1 1xGbE Fiber Adapter for System x 4 00AG510 A56L Intel I350 T2 2xGbE BaseT Adapter for System x 4 00AG520 A56M Intel I350 T4 4xGbE...

Page 20: ...t HBA for System x 3 00Y3337 A3KW QLogic 16Gb FC Single port HBA for System x 3 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for System x 3 Fibre Channel 8 Gb 42D0485 3580 Emulex 8 Gb FC Single port HBA for System x 3 42D0494 3581 Emulex 8 Gb FC Dual port HBA for System x 3 42D0501 3578 QLogic 8 Gb FC Single port HBA for System x 3 42D0510 3579 QLogic 8 Gb FC Dual port HBA for System x 3 46M6049 3589...

Page 21: ... power supplies come with one or two speed controlled non redundant fans model dependent see Table 2 The second fan is required if two or more adapters are installed and the fan is configured by selecting the appropriate Thermal Solution Fan Kit as listed in the following table If you want to operate the server in an environment up to 40 C 104 F use the optional Operating Temperature Enhancement K...

Page 22: ...t Protocol SNMP Version 3 Common Information Model CIM Web browser The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue screen capture features The remote presence feature provides the following functions Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors regardless of the system sta...

Page 23: ...ix shtml Physical and electrical specifications Dimensions and weight compact tower systems with a fixed power supply Height 360 mm 14 2 in Width 180 mm 7 1 in Depth 480 mm 18 9 in Weight Minimum ship configuration 10 kg 22 0 lb o Maximum ship configuration 13 kg 28 7 lb o Dimensions and weight standard tower systems with redundant hot swap power supplies Height 439 mm 17 3 in Width 217 mm 8 6 in ...

Page 24: ... maximum Input kilovolt amperes Minimum configuration 0 035 kVA o Maximum configuration 0 350 kVA o 300 watt power supply 100 127 nominal V ac 50 60 Hz 7 0 A maximum 200 240 nominal V ac 50 60 Hz 3 5 A maximum Input kilovolt amperes Minimum configuration 0 035 kVA o Maximum configuration 0 350 kVA o Environmental data BTU output Ship configuration 341 Btu hr 100 watts Full configuration 1726 Btu h...

Page 25: ...or Linux software VMware IBM Systems Director The following table explains warranty service definitions in more detail Table 20 Warranty service definitions Term Description Onsite repair A service technician comes to the server s location for equipment repair 24x7x2 hour A service technician is scheduled to arrive at your customer s location within two hours after remote problem determination is ...

Page 26: ...lass A Australia New Zealand AS NZS CISPR 22 Class A AS NZS 60950 1 IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 1 GB9254 Class A and GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia Belorussia and Kazakhstan TR CU 020 2011 for EMC and TR CU004 2011 for safety IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN55024 E...

Page 27: ... 90Y4318 A2MD ServeRAID M5100 Series SSD Caching Enabler 1 90Y4273 A2MC ServeRAID M5100 Series SSD Performance Key 1 81Y4546 A1X3 ServeRAID M5100 Series RAID 6 Upgrade 1 Feature on Demand upgrades for the M5225 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade for Systems FoD 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator for Systems FoD 1 47C8712 A3Z8 ServeRAID M5200 Series SSD Ca...

Page 28: ...SAS SATA Controller ships standard without a cache One of the available cache upgrades 81Y4484 81Y4487 or 81Y4559 is required for the M5120 adapter operations and it must be purchased together with the controller For more information about the ServeRAID M5120 see the Lenovo Press Product Guide at http lenovopress com tips0858 The ServeRAID M5120 SAS SATA Controller supports connectivity to the ext...

Page 29: ...een external expansion enclosures and the ServeRAID M5120 SAS SATA Controller Table 23 External SAS cables for external storage expansion enclosures Part number Feature code Description Quantity supported per one enclosure Cables for use with M5120 controller 39R6531 3707 3 m SAS Cable 1 39R6529 3708 1 m SAS Cable 1 Cables for use with M5225 controller 00Y2459 0 6m SAS Cable mSAS HD to mSAS 1 00Y2...

Page 30: ...wing table lists the hard disk drives that are supported by EXP2524 external expansion enclosures Table 25 Drive options for EXP2524 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 2 5 NL SAS HS HDDs 00NC571 1TB 7 200 rpm 6Gb SAS NL 2 5 HDD 24 2 5 SAS HS HDDs 00NC561 146GB 15 000 rpm 6Gb SAS 2 5 HDD 24 00NC563 300GB 15 000 rpm 6Gb SAS 2 5 HDD 24 0...

Page 31: ... SFF Dual Control Enclosure 6099L2C IBM Storwize V3700 3 5 inch Storage Controller Unit 6099S2C IBM Storwize V3700 2 5 inch Storage Controller Unit 6099T2C IBM Storwize V3700 2 5 inch DC Storage Controller Unit 6194L2C IBM Storwize V5000 LFF Control Enclosure 6194LEU IBM Storwize V5000 LFF Expansion Enclosure 6194S2C IBM Storwize V5000 SFF Control Enclosure 6194SEU IBM Storwize V5000 SFF Expansion...

Page 32: ...ternal USB 3 0 Dock with 1TB Cartridge 49Y9898 Half High LTO Gen 5 Internal SAS Tape Drive 00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive External backup units 362532Y RDX External USB 3 0 Dock with 320GB Cartridge 362550Y RDX External USB 3 0 Dock with 500GB Cartridge 36251TY RDX External USB 3 0 Dock with 1TB Cartridge 3628L5X Half High LTO Gen 5 External SAS Tape Drive with US line...

Page 33: ...0952F RackSwitch G8052F 10 Gb top of rack switches 7309DRX RackSwitch G8264CS Rear to Front 7309DFX RackSwitch G8264CS Front to Rear 7309BR6 RackSwitch G8124ER 7309BF7 RackSwitch G8124EF 7309G64 RackSwitch G8264R 730964F RackSwitch G8264F 7309CR9 RackSwitch G8264TR 7309CF9 RackSwitch G8264TF 40 Gb top of rack switches 8036BRX RackSwitch G8332 Rear to Front 8036BFX RackSwitch G8332 Front to Rear 80...

Page 34: ...S 200 240VAC 55946KX RT6kVA 3U Rack or Tower UPS 200 240VAC 55948KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55948PX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Rack mounted UPS units 53951AX 1500VA LCD 2U Rack UPS 100V 120V 53951KX 1500VA LCD 2U Rack UPS 230V 53952AX 2200VA LCD 2U Rack UPS...

Page 35: ...46M4137 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ultra Density Enterprise PDU C19 PDU WW 71763MU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 71763NU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 39M2816 DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC3...

Page 36: ...39Y8957 DPI Universal Rack PDU w UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU w China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI Universal Rack PDU India 0U Basic PDUs 46M4122 0U 24 C13 16A 3 Phase PDU 46M4125 0U 24 C13 30A 3 Phase PDU 46M4128 0U 24 C13 30A PDU 46M4131 0U 24 C13 32A PDU 46M4140 0U 12 C19 12 C13...

Page 37: ... systems with fixed power supplies 93072PX 25U Static S2 Standard Rack 93072RX 25U Standard Rack 93074RX 42U Standard Rack 93074XX 42U Standard Rack Extension 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 93604EX 42U 1200 mm Deep Dynamic Expansion Rack 93604PX 42U 1200 mm Deep Dynamic Rack 93614EX 42U 1200 mm Deep Static Expansion Rack 93614PX 42U 1200 mm Deep Static Rack 93624...

Page 38: ...agement Gateway 6000 1754D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager LCM8 Console cables 00AK142 A4X4 UM KVM Module VGA SD Dual RJ45 43V6147 3757 Single Cable USB Conversion Option UCO 39M2895 3756 USB Conversion Option 4...

Page 39: ...ms processes and flexible policies support our goal of providing customers with a positive experience We finance your entire solution Unlike others we allow you to bundle everything you need from hardware and software to service contracts installation costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Ou...

Page 40: ...x3100m5 System x3100 M5 Installation and Service Guide http ibm com support System x Information Center http publib boulder ibm com infocenter systemx documentation ServerProven hardware compatibility page for the x3100 M5 http www ibm com systems info x86servers serverproven compat us xseries 5457 html Configuration and Option Guide http www ibm com systems xbc cog xREF System x Reference http le...

Page 41: ...cation Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo pro...

Page 42: ...blished Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Lenovo RackSwitch Lenovo logo ServeRAID ServerGuide ServerProven System x The following terms are trademarks of oth...

Reviews: