For some server models, your server comes with an expansion drive cage. You can install up to four 2.5-inch
SAS/SATA drives to the cage.
3
Drive activity LED
4
Drive status LED
Each hot-swap drive has two LEDs.
Drive LED
Status
Description
3
Drive activity LED (left)
Solid green
The drive is powered but not active.
Blinking green
The drive is active.
4
Drive status LED (right)
Solid yellow
The drive has an error.
Blinking yellow (blinking slowly, about one
flash per second)
The drive is being rebuilt.
Blinking yellow (blinking rapidly, about four
flashes per second)
The RAID controller is locating the drive.
5
Foot stands
For tower-form-factor models, your server comes with four foot stands. To help the server stand steadily,
ensure that you install the foot stands correctly as shown. See “Install the foot stands” on page 64.
6a 6b 6c 6d 7a 7b
Drive bays
The drive bays are used to install 3.5-inch or 2.5-inch storage drives. The EMI integrity and cooling of the
server are protected by having all drive bays occupied. The vacant drive bays must be occupied by drive bay
fillers or drive fillers. When you install drives, follow the order of the drive bay numbers.
Note:
For the 2.5-inch-drive-bay models that support NVMe drives, you can install up to four NVMe drives in
bays 4–7.
Front panel
The front panel of the server provides controls, connectors, and LEDs.
The following illustration shows the control, connectors, and LEDs on the front panel of the server.
Figure 6. Front panel
16
ThinkSystem ST550 Maintenance Manual
Summary of Contents for ThinkSystem ST550 7X09
Page 1: ...ThinkSystem ST550 Maintenance Manual Machine Types 7X09 and 7X10 ...
Page 8: ...vi ThinkSystem ST550 Maintenance Manual ...
Page 36: ...28 ThinkSystem ST550 Maintenance Manual ...
Page 188: ...180 ThinkSystem ST550 Maintenance Manual ...
Page 206: ...198 ThinkSystem ST550 Maintenance Manual ...
Page 210: ...202 ThinkSystem ST550 Maintenance Manual ...
Page 219: ......
Page 220: ......