• Online KCS access (unauthenticated and user restricted): You do not need to specify a
value for
access_method
when you use this access method.
Note:
The KCS access method uses the IPMI/KCS interface, which requires that the IPMI
driver be installed.
The following commands are examples of not using the user ID and password default
values:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Remote LAN access, type the command:
Note:
When using the remote LAN access method to access Lenovo XClarity Controller
using the LAN from a client, the
host
and the
xcc_external_ip
address are required
parameters.
[−−imm xcc_user_id:xcc_password@xcc_external_ip]
or
[−−bmc xcc_user_id:xcc_password@xcc_external_ip]
Where:
xcc_external_ip
The BMC/IMM/XCC LAN IP address. There is no default value. This parameter is
required.
xcc_user_id
The BMC/IMM/XCC account (1 of 12 accounts). The default value is USERID.
xcc_password
The BMC/IMM/XCC account password (1 of 12 accounts). The default value is
PASSW0RD (with a zero 0 not an O).
Note:
BMC, IMM, or XCC internal LAN/USB IP address, account name, and password are
all valid for this command.
Examples that do use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> --host <xcc_ip>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> --host <xcc_ip>
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> --host <xcc_ip>
Step 2. Restart the solution.
Enable TPM/TCM
The server supports Trusted Platform Module (TPM), Version 1.2 or Version 2.0
Note:
For customers in the People’s Republic of China, integrated TPM is not supported. However,
customers in the People’s Republic of China can install a Trusted Cryptographic Module (TCM) adapter or a
TPM adapter (sometimes called a daughter card).
When a system board is replaced, you must make sure that the TPM/TCM policy is set correctly.
CAUTION:
Take special care when setting the TPM/TCM policy. If it is not set correctly, the system board can
become unusable.
.
Hardware replacement procedures
175
Summary of Contents for ThinkSystem ST550 7X09
Page 1: ...ThinkSystem ST550 Maintenance Manual Machine Types 7X09 and 7X10 ...
Page 8: ...vi ThinkSystem ST550 Maintenance Manual ...
Page 36: ...28 ThinkSystem ST550 Maintenance Manual ...
Page 188: ...180 ThinkSystem ST550 Maintenance Manual ...
Page 206: ...198 ThinkSystem ST550 Maintenance Manual ...
Page 210: ...202 ThinkSystem ST550 Maintenance Manual ...
Page 219: ......
Page 220: ......