If you are instructed to return the old simple-swap drive backplate assembly, follow all packaging
instructions and use any packaging materials that are provided.
Install the simple-swap drive backplate assembly
Use this information to install the simple-swap drive backplate assembly.
Ground package before opening”
Before installing the simple-swap drive backplate assembly, touch the static-protective package that
contains the new backplate assembly to any unpainted surface on the outside of the server. Then, take the
new backplate assembly out of the package and place it on a static-protective surface.
To install the simple-swap drive backplate assembly, complete the following steps:
Figure 49. Simple-swap drive backplate assembly installation
Step 1. Put the backplate assembly under the front I/O assembly cables, align it with the chassis, and lower
it into the chassis. Put the backplate assembly into place with it leaning backward slightly so that
the three pins
1
on the chassis pass through the three holes
2
in the assembly.
Step 2. Close the release latches to secure the backplate assembly in place.
.
Hardware replacement procedures
77
Summary of Contents for ThinkSystem SR530
Page 1: ...ThinkSystem SR530 Maintenance Manual Machine Types 7X07 and 7X08 ...
Page 8: ...vi ThinkSystem SR530 Maintenance Manual ...
Page 24: ...16 ThinkSystem SR530 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR530 Maintenance Manual ...
Page 72: ...64 ThinkSystem SR530 Maintenance Manual ...
Page 74: ...66 ThinkSystem SR530 Maintenance Manual ...
Page 170: ...162 ThinkSystem SR530 Maintenance Manual ...
Page 174: ...166 ThinkSystem SR530 Maintenance Manual ...
Page 178: ...170 ThinkSystem SR530 Maintenance Manual ...
Page 183: ......
Page 184: ......