© Copyright Lenovo 2019
Chapter 3: Installing NE10032 Hardware and Options
51
Installing the Air-Duct Option
The NE10032 supports an optional 1U air duct to maximize air flow conditions in a
19” rack.
The air-duct option is only supported when the switch is installed on a 4-post rack
mount kit basis. If the switch is installed on a rack using default 2-post rack mount
kit, it does not support the air-duct option.
For information on removing an installed 1U air-duct option, see
The following table lists the parts included with the air-duct option kit.
Attention:
The rack-mounting frame may not be able to support the weight of the
networking switch with only the front post mounting brackets (2-post application).
If the switch has an undesirable amount of sag, it is recommended to use a 4-post
mounting kit.
Attention:
For earthquake stability, mount the switch in a 4-post rack.
Table 13.
Air-duct Option Kit parts
Item Number
Description
Quantity
1
Cable tie
4
2
1U Duct sleeve (long)
1
3
Mounting bracket (left)
1
4
Mounting bracket (right)
1
5
Foam carrier assembly
2
6
M3.5 screws
6
1
6
5
Summary of Contents for ThinkSystem NE10032
Page 6: ...6 Lenovo NE10032 Installation Guide ...
Page 16: ...16 NE10032 Installation Guide ...
Page 58: ...58 NE10032 Installation Guide ...
Page 76: ...76 NE10032 Installation Guide ...
Page 92: ...92 NE10032 Installation Guide ...
Page 108: ...108 NE10032 Installation Guide ...
Page 114: ...114 NE10032 Installation Guide ...