Note:
If there is any PCIe card installed on the system board, it might block your access to the heat sink
and fan assembly. In this case, remove the PCIe card. See “Removing a PCIe card” on page 58.
4. Remove the four screws that secure the heat sink and fan assembly to the system board. It is
recommended that you carefully remove the four screws from the system board using the following
method to avoid any possible damage to the system board.
a. Partially remove screw
1
, then completely remove screw
2
, and then return to screw
1
and
completely remove it.
b. Partially remove screw
3
, then completely remove screw
4
, and then return to screw
3
and
completely remove it.
Note:
The four screws are integrated parts of the heat sink and fan assembly. Do not try to remove the
four screws from the heat sink and fan assembly.
Figure 74. Removing the screws that secure the heat sink and fan assembly
5. Gently twist the heat sink and fan assembly to free it from the CPU, and then lift the heat sink and
fan assembly off the system board.
6. If you are instructed to return the old heat sink and fan assembly, follow all packaging instructions and
use any packaging materials that are supplied to you for shipping.
Installing the heat sink and fan assembly
To install the heat sink and fan assembly, do the following:
1. Prepare your server and remove the server cover. See “Preparing your server in advance and removing
2. Lay the server on its side for easier operation.
98
ThinkServer TS450 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer TS450
Page 14: ...xii ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 48: ...34 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 64: ...50 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 142: ...128 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 152: ...China RoHS 138 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 154: ...140 ThinkServer TS450 User Guide and Hardware Maintenance Manual ...
Page 165: ......
Page 166: ......