![Lenovo ThinkServer TD350 User Manual And Hardware Maintenance Manual Download Page 132](http://html.mh-extra.com/html/lenovo/thinkserver-td350/thinkserver-td350_user-manual-and-hardware-maintenance-manual_203018132.webp)
Installing or removing the intrusion switch
The intrusion switch informs you that the server cover is not properly installed or closed by creating an event
in the system event log (SEL). You can purchase an intrusion switch from the Lenovo Web site at:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
Installing the intrusion switch
Attention:
Do not open your server or attempt any repair before reading and understanding “Read this first: safety
information” on page iii and “Guidelines” on page 69.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note:
Use any documentation that comes with the intrusion switch and follow those instructions in addition
to the instructions in this topic.
To install the intrusion switch, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 72.
4. Remove the cooling shroud. See “Removing and reinstalling the cooling shroud” on page 74.
5. Touch the static-protective package that contains the intrusion switch to any unpainted surface on the
outside of the server. Then, take the intrusion switch out of the package.
6. Insert the intrusion switch into the chassis. Then, push the new intrusion switch in the direction
as shown until it is seated securely.
Figure 73. Installing the intrusion switch
7. Connect the intrusion switch cable to the intrusion switch connector on the system board. See “System
118
ThinkServer TD350 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer TD350
Page 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 213: ...China RoHS Appendix A Notices 199 ...
Page 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 225: ......
Page 226: ......