Chapter 4: Ctrl-R Utility
Viewing and Changing Device Properties
4.13.11
Managing BBU Information
If your SAS controller has a BBU, you can view information about it and change some settings.
A learning cycle is a battery calibration operation that the controller performs periodically to determine the condition
of the battery.
Perform the following steps to view and change the battery settings:
1.
Navigate to the second
Controller Settings
screen and select
Manage Battery
.
The
Battery Properties
dialog appears. Most of the battery properties are read only.
Figure 59 Battery Properties
If the
Battery State
field has a value other than
Optimal
, the
Non-Optimal Reason
field appears at the bottom of
the
Battery Properties
dialog. The
Non-Optimal Reason
field is a read-only field and states a reason for the non
optimal state of the battery.
2.
Select a battery learn mode from the
Learn Mode
drop-down list.
The values in the drop-down list differ based on whether the battery supports transparent learn cycles.
—
If the battery supports transparent learn, the following values appear in the
Learn Mode
drop-down list:
Transparent
– The firmware tracks the time since the last learning cycle and performs a learn cycle when
it is due.
Disabled
– The firmware does not monitor or initiate a learning cycle. You can schedule learning cycles
manually.
Unknown
– The firmware warns about a pending learning cycle. You can start a learning cycle manually.
After the learning cycle completes, the firmware resets the counter and warns you when the next
learning cycle time is reached.
—
If the battery does not support transparent learn, the following values appear in the
Learn Mode
drop-down
list:
Automatic
– The firmware tracks the time since the last learning cycle and performs a learn cycle when
due. Write caching need not be disabled.
Disabled
– The firmware does not monitor or initiate a learning cycle. You can schedule learning cycles
manually.
Disabled (Warning Only)
– The firmware never initiates a battery learn cycle but notifies you through
events when a learn cycle is needed.