LSI Corporation
- 64 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 4: Ctrl-R Utility
Creating a Storage Configuration
3.
Enter a name for the CacheCade virtual drive in the
Name
field.
4.
Select a SSD from the
Select SSD
box.
5.
Press
OK
.
A message appears, stating that the CacheCade virtual drive has been created.
4.7.5
Modifying a CacheCade Pro 2.0 Virtual Drive
You can modify the name and the write policy of an existing CacheCade virtual drive any time after a CacheCade
virtual drive is created.
Perform the following steps to modify the CacheCade virtual drive:
1.
In the
VD Mgmt
screen, navigate to the CacheCade virtual drive. and press the F2 key.
2.
Navigate to
Properties
, and press Enter.
The following dialog appears.
Figure 36 Modifying CacheCade Virtual Drive
3.
You can rename a CacheCade virtual drive in the
CacheCade Virtual Drive Name
field.
4.
You can also modify the write policy by selecting one from the
Write Policy
field.
5.
Press
OK
.
To view the virtual drives associated with this CacheCade virtual drive, click
Associated VDs
in the above dialog.
The
Associated Virtual Drives
dialog appears.
Summary of Contents for ThinkServer RD650
Page 1: ...ThinkServer 12 Gb s MegaRAID SAS Software User Guide ...
Page 417: ......