LSI Corporation
- 226 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 7: MegaRAID Storage Manager Overview and Installation
MegaRAID Storage Manager Remotely Connecting to VMware ESX
145.147.201.88:1234 testComm
#################################################
NOTE
Solaris also supports Custom community support.
3.
If in case, ’TrapDestInd’ above is set to 1, IP addresses shall be taken from
/etc/sma/snmp/snmpd.conf
file in
the following format:
’com2sec snmpclient 172.28.157.149 public’
’Trapsink’
and
’TrapCommunity’
tokens are supported for sending customized SNMP traps
NOTE
In Solaris 11 x86, the file will be taken from
/etc/net-snmp/snmp/snmpd.conf.
4.
Start the LSI SAS SNMP Agent by entering the following command:
#/etc/init.d/lsi_mrdsnmpd start
7.6.5.7
Uninstalling the SNMP Package
The
uninstall.sh
script is located under the
/etc/lsi_mrdsnmp/sas
directory. Use the following command
to uninstall the package:
# cd /etc/lsi_mrdsnmp/sas
# ./uninstall.sh
7.7
MegaRAID Storage Manager Remotely Connecting to VMware ESX
When the MegaRAID Storage Manager software is used to connect to a VMware ESX machine from a remote machine
(Windows /Linux), for long running operations (such as volume creation, deletion) to complete in a shorter time,
perform the following steps:
1.
Login to the VMware ESX machine.
2.
Open
/etc/sfcb/sfcb.cfg
.
3.
Increase the keepaliveTimeout value from 1 to 100 or to a higher value.
4.
Restart
sfcbd
(
/etc/init.d/sfcbd-watchdog restart
).
5.
Restart the MegaRAID Storage Manager Framework on the MegaRAID Storage Manager client machine.
—
For Windows – Restart the framework service.
—
For Linux – Restart the vivaldi framework service.
6.
Relaunch the
MegaRAID Storage Manager
window.
7.8
Prerequisites to Running MegaRAID Storage Manager Remote Administration
The MegaRAID Storage Manager software requires ports 3071 and 5571 to be open to function. Follow these steps to
prepare to run the MegaRAID Storage Manager Remote Administration.
1.
Configure the system with a valid IP address.
Make sure the IP address does not conflict with another in the sub network.
Ports, such as 3071 and 5571, are open and available for the MegaRAID Storage Manager framework
communication.
2.
Disable all security manager and firewall.
3.
Configure the multicasting.
Summary of Contents for ThinkServer RD650