• An error in the Lenovo XClarity Controller interface.
• Not all memory is detected. For example, the appliance should have 256 GB per node and the host only
shows 240 GB.
Remove a DIMM
Use this information to remove a DIMM.
Ground package before opening”
Attention:
• Disconnect all power cords for this task.
• DIMMs are sensitive to static discharge and require special handling. In addition to the standard
guidelines for Handling static-sensitive devices:
– Always wear an electrostatic-discharge strap when removing or installing DIMMs. Electrostatic-
discharge gloves can also be used.
– Never hold two or more DIMMs together so that they touch. Do not stack DIMMs directly on top of
each other during storage.
– Never touch the gold DIMM connector contacts or allow these contacts to touch the outside of the
DIMM connector housing.
– Handle DIMMs with care: never bend, twist, or drop a DIMM.
Before removing a DIMM:
1. Identify the failed DIMM by either checking the event logs in UEFI setup or use the Lenovo XClarity
Controller Web console to browse the post event log. The event log contains information about the
location of the DIMM fault.
2. Place the node in maintenance mode by following the procedure
in the
3. Power off the node and if the cable management arm is not in place, disconnect all the cables.
4. Remove the appliance from the rack.
5. Remove the top cover.
6. If your server comes with an air baffle, remove it first.
To remove a DIMM, complete the following steps:
68
User Guide for ThinkAgile HX2320 Appliance and HX2321 Node
Summary of Contents for ThinkAgile HX2320 Appliance
Page 4: ...ii User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 16: ...12 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 32: ...28 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 38: ...34 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 86: ...82 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 90: ...86 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 92: ...88 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 94: ...90 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 96: ...92 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 99: ......
Page 100: ......