DIMM
Retaining
clip
Retaining
clip
6. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the
outside of the server. Then, remove the DIMM from the package.
7. Turn the DIMM so that the DIMM keys align correctly with the connector.
8. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the
DIMM connector (see “System-board optional-device connectors” on page 32 for the locations of
the DIMM connectors).
9. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated
in the connector.
Note:
If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly
inserted; open the retaining clips, remove the DIMM, and then reinsert it.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation” on
page 123.
Installing drives
The types of drives that the server supports are described in this section.
The following notes describe the type of drives that the server supports and other information
that you must consider when you install a drive. For a list of supported drives, see
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
• Locate the documentation that comes with the drive and follow those instructions in addition to the
instructions in this chapter.
• The server supports one optional ultra-slim SATA CD-RW/DVD-ROM optical drive.
• The server can support up to 16 2.5-inch drives, up to 32 1.8-inch drives, or a combination of both
2.5-inch and 1.8-inch hot-swap drives, when you use the supported SAS/SATA backplane configurations
and/or required RAID Option Adapter additions. The server supports 2.5-inch hot-swap SAS or hot-swap
55
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...