Step 3.
Replace the fan cage assembly, if you removed it (see “Replacing the fan cage assembly” on
page 126).
Step 4.
Reconnect the cables (see “Connecting the cables” on page 128).
Step 5.
If you removed the server cover, replace it (see “Replacing the server top cover” on page 127).
Step 6.
Reconnect the power cords.
Step 7.
Start the server. Confirm that is starts correctly and recognizes the newly installed devices, and
make sure that no error LEDs are lit.
Step 8.
Update the server configuration (see “Updating the server configuration” on page 129).
Step 9.
(Business Partners only) Complete the additional steps in “Instructions for Business Partners”
on page 25.
Step 10. Install the server in the rack (see the
Rack Installation Instructions
that come with the server for
instructions).
Replacing the DIMM air baffle
Use this information to replace the DIMM air baffle.
To install the DIMM air baffle, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
Align the tabs on the sides of the DIMM air baffle with the slots on the sides of the chassis wall
and lower the DIMM air baffle into the server.
00000
00000
00000
00000
000
000
000
000
000
000
000
000
000
000
000
000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
DIMM air baffle
Replacing the microprocessor air baffle
Use this information to replace the microprocessor air baffle.
124
Lenovo System x3750 M4 Installation and Service Guide
Summary of Contents for System x3750 M4
Page 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Page 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Page 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Page 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Page 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Page 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Page 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Page 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Page 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Page 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Page 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Page 981: ......
Page 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...