Note:
When using the remote LAN access method to access IMM2 using the LAN from a client,
the
host
and the
imm_external_ip
address are required parameters.
[imm imm_user_id:imm_password@imm_externaln _ip]
Where:
imm_external_ip
The external IMM2 LAN IP address. There is no default value. This parameter is required.
imm_user_id
The IMM2 account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM2 account password (1 of 12 accounts). The default value is PASSW0RD (with
a zero 0 not an O).
Example that does not use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SYsInfoUUID <uuid_value> [imm imm_user_id:imm_password@imm_internal_ip]
Example that does use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
• Bootable media:
You can also build a bootable medium using the applications available through the ToolsCenter
Web site at https://support.lenovo.com/us/en/ documents/LNVO-CENTER. From the
ToolsCenter
page, scroll down for the available tools.
Step 5.
Restart the IMM.
Step 6.
Restart the server.
Updating the DMI/SMBIOS data
The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use the
Advanced Settings Utility to update the DMI in the UEFI-based server.
The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use Lenovo
ToolsCenter Suite CLI to update the DMI in the UEFI-based server. Lenovo ToolsCenter Suite CLI is an online
tool that supports several operating systems. Make sure that you download the version for your operating
system. You can download Lenovo ToolsCenter Suite CLI from the Lenovo Web site. To download Lenovo
ToolsCenter Suite CLI and update the DMI, do the following:
Note:
Changes are made periodically to the Lenovo Web site. The actual procedure might vary slightly
from what is described in this document.
Step 1.
Go to https://support.lenovo.com/us/en/documents/LNVO-TCLI. Then, find and download Lenovo
ToolsCenter Suite CLI version for your operating system.
Step 2.
Lenovo ToolsCenter Suite CLI sets the DMI in the Integrated Management Module 2.1 (IMM2.1).
Select one of the following methods to access the Integrated Management Module 2.1 (IMM2.1)
to set the DMI:
• Online from the target system, such as LAN or keyboard console style (KCS) access
• Remote access to the target system (LAN based)
• Bootable medium containing Lenovo ToolsCenter Suite CLI (LAN or KCS, depending upon
the bootable media)
Step 3.
Copy and unpack the Lenovo ToolsCenter Suite CLI package, which also includes other required
files, to the server. Make sure that you unpack the Lenovo ToolsCenter Suite CLI and the required
files to the same directory. In addition to the application executable (OneCLI or OneCLI64), the
following files are required:
.
49
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......