ServeRAID M5120 SAS/SATA Controller User’s Guide
C-1
Appendix C Glossary
of Terms and
Abbreviations
active
termination
The electrical connection required at each end of the SCSI bus,
composed of active voltage regulation and a set of termination resistors.
array
An array, or group, of drives combines the storage space on the drives
into a single segment of storage space. A hot spare drive does not
actively participate in the array.
BIOS
Acronym for Basic Input/Output System. Software that provides basic
read/write capability. Usually kept as firmware (ROM-based). The system
BIOS on the mainboard of a computer boots and controls the system.
The BIOS on your host controller acts as an extension of the system
BIOS.
configuration
Refers to the way a computer is set up, the combined hardware
components (computer, monitor, keyboard, and peripheral devices) that
make up a computer system, or the software settings that allow the
hardware components to communicate with each other.
device driver
A program that allows a microprocessor (through the operating system)
to direct the operation of a peripheral device.
domain
validation
Domain Validation is a software procedure in which a host queries a
device to determine its ability to communicate at the negotiated data rate.
EEPROM
Acronym for Electronically Erasable Programmable Read-Only Memory.
It is a memory chip that typically stores configuration information, as it
provides stable storage for long periods without electricity and can be
reprogrammed. Refer to NVRAM.
external SAS
device
A SAS device installed outside the computer cabinet. These devices are
connected using specific types of shielded cables.
Fusion-MPT
architecture
Fusion-MPT (Message Passing Technology) architecture consists of
several main elements: Fusion-MPT firmware, the Fibre Channel and
Summary of Contents for ServeRAID M5120
Page 1: ...ServeRAID M5120 SAS SATA Controller USER S GUIDE ...
Page 3: ...iii Safety ...
Page 4: ...iv ...
Page 5: ...v ...
Page 6: ...vi Safety Statements ...
Page 7: ...vii ...
Page 8: ...viii ...
Page 10: ...x ...
Page 14: ...xiv Contents ...
Page 16: ...xvi Contents ...
Page 18: ...xviii Contents ...
Page 55: ...A 2 Getting Help and Technical Assistance A 1 Before You Call ...
Page 58: ...Taiwan Product Service A 5 A 6 Taiwan Product Service ...
Page 59: ...ServeRAID M5120 SAS SATA Controller User s Guide B 1 Appendix B Notices ...
Page 60: ...B 2 Notices B 1 Trademarks ...
Page 61: ...Important Notes B 3 B 2 Important Notes ...
Page 64: ...B 6 Notices B 5 4 European Union EMC Directive Conformance Statement ...
Page 65: ...Electronic Emission Notices B 7 B 5 5 Germany Class A Statement ...
Page 66: ...B 8 Notices B 5 6 Japan VCCI Class A Statement ...
Page 68: ...B 10 Notices B 5 10 Taiwan Class A Compliance Statement ...
Page 74: ...P N 81Y1008 ...