1
2
3.5-inch Hard disk
drive cage
3.5-inch Hard disk drive
Release latch
Figure 90. 3.5-inch hard disk drive removal
If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Installing a 3.5-inch hard disk drive
Use this information to install a 3.5-inch SAS/SATA hard disk drive.
Before installing a 3.5-inch hard disk drive, read the following information:
• Inspect the drive tray for signs of damage.
• To maintain proper system cooling, do not operate the server for more than 10 minutes without either a
drive or a filler panel installed in each drive bay.
To install a 3.5-inch SAS/SATA hard disk drive, complete the following steps.
Step 1.
Read “Safety” on page v and “Installation guidelines” on page 101.
Step 2.
If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see “Removing a
compute node from a chassis” on page 104 for instructions).
Step 3.
Carefully lay the compute node on a flat, static-protective surface, orienting the compute node
with the bezel pointing toward you.
Step 4.
Remove the cover (see “Removing the compute node cover” on page 113).
Step 5.
Touch the static-protective package that contains the disk drive to any unpainted metal surface on
the server; then, remove the disk drive from the package and place it on a static-protective surface.
Step 6.
Align the drive with the guide rails in the bay; then, carefully slide the drive assembly into the drive
bay until the drive snaps into place.
Removing and replacing components
165
Summary of Contents for NeXtScale nx360 M5
Page 1: ...Lenovo NeXtScale nx360 M5 Installation and Service Guide Machine Type 5465 ...
Page 42: ...28 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 98: ...84 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 114: ...100 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 242: ...228 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 818: ...804 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1002: ...988 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1009: ...Taiwan Class A compliance statement Appendix E Notices 995 ...
Page 1010: ...Taiwan BSMI RoHS declaration 996 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1012: ...998 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1020: ...1006 Lenovo NeXtScale nx360 M5 Installation and Service Guide ...
Page 1021: ......
Page 1022: ...Part Number 00MV789 Printed in China 1P P N 00MV789 1P00MV789 ...