– Has this configuration ever worked?
– What changes, if any, were made before the configuration failed?
– Is this the original reported failure?
• Diagnostic program type and version level
• Hardware configuration (print screen of the system summary)
• UEFI firmware level
• IMM firmware level
• Operating system software
You can solve some problems by comparing the configuration and software setups between working and
nonworking servers. When you compare servers to each other for diagnostic purposes, consider them
identical only if all the following factors are exactly the same in all the servers:
• Machine type and model
• UEFI firmware level
• IMM firmware level
• Adapters and attachments, in the same locations
• Address jumpers, terminators, and cabling
• Software versions and levels
• Diagnostic program type and version level
• Configuration option settings
• Operating-system control-file setup
See Appendix D “Getting help and technical assistance” on page 845 for information about calling Lenovo
for service.
Recovering the server firmware (UEFI update failure)
Use this information to recover the server firmware.
Important:
Some cluster solutions require specific code levels or coordinated code updates. If the device is
part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
If the server firmware has become corrupted, such as from a power failure during an update, you can recover
the server firmware in the following way:
•
In-band method:
Recover server firmware, using either the boot block jumper (Automated Boot
Recovery) and a server Firmware Update Package Service Pack.
•
Out-of-band method:
Use the IMM2.1 web interface to update the firmware, using the latest server
firmware update package.
Notes:
You can obtain a server update package from one of the following sources:
• Download the server firmware update from the World Wide Web.
• Contact your Lenovo service representative.
To download the server firmware update package from the World Wide Web, go to http://www.lenovo.com/
support.
82
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......