To find service bulletins that are available for the NeXtScale nx360 M5 water-cooled technology tray server,
go to http://www.lenovo.com/support and search for
5467, 5468, and 5469
, and
retain
.
Checkout procedure
The checkout procedure is the sequence of tasks that you should follow to diagnose a problem in the server.
About the checkout procedure
Before you perform the checkout procedure for diagnosing hardware problems, review the following
information:
• Read the safety information that begins on page “Safety” on page v.
• Lenovo Dynamic System Analysis (DSA) provides the primary methods of testing the major components
of the server, such as the system board, Ethernet controller, keyboard, mouse (pointing device), serial
ports, and hard disk drives. You can also use them to test some external devices. If you are not sure
whether a problem is caused by the hardware or by the software, you can use the diagnostic programs to
confirm that the hardware is working correctly.
• When you run DSA, a single problem might cause more than one error message. When this happens,
correct the cause of the first error message. The other error messages usually will not occur the next time
you run DSA.
Important:
If multiple error codes or light path diagnostics LEDs indicate a microprocessor error, the error
might be in the microprocessor or in the microprocessor socket. See “Microprocessor problems” on page
70 for information about diagnosing microprocessor problems.
• Before you run DSA, you must determine whether the failing server is part of a shared hard disk drive
cluster (two or more servers sharing external storage devices). If it is part of a cluster, you can run all
diagnostic programs except the ones that test the storage unit (that is, a hard disk drive in the storage
unit) or the storage adapter that is attached to the storage unit. The failing server might be part of a cluster
if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers sharing external storage
devices).
– One or more external storage units are attached to the failing server and at least one of the attached
storage units is also attached to another server or unidentifiable device.
– One or more servers are located near the failing server.
Important:
If the server is part of a shared hard disk drive cluster, run one test at a time. Do not run any
suite of tests, such as “quick” or “normal” tests, because this might enable the hard disk drive diagnostic
tests.
• If the server is halted and a POST error code is displayed, see Appendix B “UEFI/POST diagnostic codes”
on page 693. If the server is halted and no error message is displayed, see “Troubleshooting by symptom”
on page 67 and “Solving undetermined problems” on page 80.
• For information about power-supply problems, see “Solving power problems” on page 79, “Power
problems” on page 75, and “Power-supply LEDs” on page 59.
• For intermittent problems, check the event log; see “Event logs” on page 62 and Appendix C “DSA
diagnostic test results” on page 715.
Performing the checkout procedure
Use this information to perform the checkout procedure.
To perform the checkout procedure, complete the following steps:
56
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...