3. Install the rear drive cage if you have removed it. See “Install the hot-swap rear drive assembly” on page
4. Install the air baffle if you have removed it. See “Install the air baffle” on page 30.
5. Install the top cover. See “Install the top cover” on page 108.
6. Push the power supplies into the bays until they click into place.
7. Connect power cords to the server and turn on the server.
8. Update the Universally Unique Identifier (UUID) and DMI/SMBIOS data with new vital product data
(VPD).
9. Enable TPM.
10. Optionally, enable Secure Boot.
Top cover replacement
Use this information to remove and install the top cover.
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S014
CAUTION:
Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is
authorized to remove the covers where the label is attached.
Remove the top cover
Use this information to remove the top cover.
About this task
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
106