Step 1.
Remove the cover (see “Removing the compute node cover” on page 643).
Step 2.
Locate the fabric connector on the system board (see “System-board layouts” on page 17).
Step 3.
Using a #1 Phillips screwdriver, loosen the four captive screws that secure the fabric connector.
Step 4.
Lift the fabric connector from the system board and store it in a safe place.
If you are instructed to return the fabric connector, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
If you have removed the fabric connector to install an I/O expansion adapter in I/O expansion connector 1,
keep the fabric connector in a safe place for future use.
Installing a fabric connector
Use this information to install a fabric connector.
Before you install a fabric connector, complete the following steps:
1. Read “Safety” on page iii and “Installation guidelines” on page 637.
2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node
from a chassis” on page 639 for instructions).
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
4. Obtain a #1 Phillips screwdriver.
To install a fabric connector, complete the following steps.
660
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...