Installing a DIMM
Use this information to install a DIMM.
Before you install a DIMM, complete the following steps:
1. Read “Safety” on page iii and “Installation guidelines” on page 637.
2. Read the documentation that comes with the DIMMs.
3. If the compute node is installed in a Flex System chassis, remove it (see “Removing a compute node
from a chassis” on page 639 for instructions).
4. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with
the bezel pointing toward you.
This component can be installed as an optional device or as a CRU. The installation procedure is the same
for the optional device and the CRU.
After you install or remove a DIMM, you must change and save the new configuration information by using
the Setup utility. When you turn on the compute node, a message indicates that the memory configuration
has changed. Start the Setup utility and select
Save Settings
(see “Using the Setup utility” on page 24
for more information) to save changes.
If you are replacing a DIMM as a result of a DIMM failure, you might have to reenable the DIMM. To reenable
the DIMM, complete the following steps:
1. Verify that the amount of installed memory is the expected amount through the operating system, by
watching the monitor as the compute node starts, by using the CMM sol
sol
sol command, or through Flex
System Manager management software.
• For more information about the CMM sol
sol
sol command, see the "Flex System
• For more information about Flex System Manager management software,
2. Run the Setup utility to reenable the DIMMs (see “Using the Setup utility” on page 24 for more
information).
The compute node supports low-profile (LP) DDR3 DIMMs with error-correcting code (ECC) in 2 GB, 4 GB,
8 GB, and 16 GB capacities.
The following illustration shows the system-board components, including the DIMM connectors.
654
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...