asu set SYSTEM_PROD_DATA.SysEncloseAssetTag
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
[–user
userid
][–password
password
]
where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
is the 33-character asset tag number of the compute
node.
Remotely over a LAN
If you omit any optional parameter, the default value is used.
To update the UUID, in the ASU command-line interface, enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoUUID
uuid
–host
ipaddress
[–user
userid
][–password
password
]
where:
uuid
is the user-assigned hexadecimal value, up to 16 bytes, that identifies the compute node.
ipaddress
is the external LAN IP address of the IMM2.
userid
is the IMM2 account name (1 of 12 accounts). The default is USERID.
password
is the IMM2 account password (1 of 12 accounts). The default is PASSW0RD (with a zero, not the
letter O).
To update the DMI/SMBIOS data, complete the following steps:
Step 1.
In the ASU command-line interface, enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoProdName
xxxxyyy
–host
ipaddress
[–user
userid
][–password
password
]
where:
xxxx
is the 4-digit machine type of the compute node.
yyy
is the 3-digit model number of the compute node.
ipaddress
is the external LAN IP address of the IMM2.
userid
is the IMM2 account name (1 of 12 accounts). The default is USERID.
password
is the IMM2 account password (1 or 12 accounts). The default is PASSW0RD (with a zero,
not the letter O).
Step 2.
Enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum
zzzzzzz
–host
ipaddress
[–user
userid
][–password
password
]
where
zzzzzzz
is the 7-character serial number of the compute node.
Step 3.
Enter the following command:
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
–host
ipaddress
[–user
userid
][–password
password
]
32
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...