Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
Event messages
Use this information to review event messages and resolve many errors.
Note:
IMM and UEFI events related to communications errors can take up to 20 minutes to be displayed
in the CMM event log.
IMM messages
When a hardware event is detected by the IMM on a Flex System x220 Compute Node, the IMM logs that
event in the system-event log in the compute node. In addition, the IMM sends that event to the CMM and to
the Flex System Manager management software (if installed).
For each event code, the following fields are displayed:
Event identifier
A hexadecimal identifier that uniquely identifies an event or class of events. In this documentation, the
event identifiers are prefixed with 0x and followed by eight characters.
Event description
The logged message string that appears for an event. When the event string is displayed in the
system-event log, information such as a specific component is displayed. In this documentation, that
additional information appears as variables, such as [arg1] or [arg2].
Explanation
Additional information to explain why the event occurred.
223
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...