background image

The Flex System FC5022 16Gb SAN Scalable Switches can be installed in bays 1, 2, 3, and 4 of the Flex

System chassis. A supported adapter card must be installed in a corresponding slot of the compute node

(slot A1 when switches are installed in bays 1 and 2 or slot A2 when switches are in bays 3 and 4).

With compute nodes that have an integrated dual-port 10 GbE network interface controller (NIC) these

switches can only be installed in bays 3 and 4 because integrated NICs ports are routed to bays 1 and 2

with a specialized periscope connector and the FC adapter card cannot be installed in slot A1. When

needed, however, the periscope connector can be replaced with an FC adapter card, in which case the

integrated NIC will be disabled and FC switches can be used in bays 1 and 2.

Table 7 shows the connections between dual-port and 4-port FC adapters installed in the compute nodes

other than x222 to the switch bays in the chassis with Flex System FC5022 16 Gb SAN Scalable Switches.

Table 7. Adapter to I/O bay correspondence

I/O adapter slot in the server

Port on the adapter

Corresponding I/O module bay in the chassis

Slot 1

Port 1

Module bay 1

Port 2

Module bay 2

Port 3

Module bay 1

Port 4

Module bay 2

Slot 2

Port 1

Module bay 3

Port 2

Module bay 4

Port 3

Module bay 3

Port 4

Module bay 4

Slot 3
(full-wide compute nodes only)

Port 1

Module bay 1

Port 2

Module bay 2

Port 3

Module bay 1

Port 4

Module bay 2

Slot 4
(full-wide compute nodes only)

Port 1

Module bay 3

Port 2

Module bay 4

Port 3

Module bay 3

Port 4

Module bay 4

Table 8 shows the connections between 4-port adapters installed in the x222 compute nodes to the switch

bays in the chassis with Flex System FC5022 16Gb SAN Scalable Switches.

Table 8. x222 adapter to I/O bay correspondence

Server

FC5024D 4-port
16Gb FC Adapter

Corresponding I/O module
bay in the chassis

Upper server

Port 1

Module bay 3

Port 2

Module bay 4

Lower server

Port 1

Module bay 3

Port 2

Module bay 4

With the x222, each node bay consumes four ports on the switch, therefore, additional port licenses might

be needed depending on your configuration (see Table 1 for FoD port upgrades).

Lenovo Flex System FC5022 16Gb SAN Scalable Switches

12

Summary of Contents for Flex System FC5022

Page 1: ...ring and management are simplified using end to end Brocade tools such as Web Tools and the Brocade Network Advisor BNA Figure 1 shows the switch module Figure 1 Lenovo Flex System FC5022 16 Gb SAN Scalable Switch Did you know Only the FC5022 provides up to 48 FC ports in an embedded form factor which provides Flex System a unique differentiation in the market including the following Increased I O...

Page 2: ...mbers for the Features on Demand upgrades include the following items Features on Demand Activation Flyer Upgrade authorization letter The switch does not include a serial management cable however Flex System Management Serial Access Cable part number 90Y9338 is supported and contains two cables a mini USB to RJ45 serial cable and a mini USB to DB9 serial cable either of which can be used to conne...

Page 3: ...on by model for Flex System FC5022 switches Table 3 Feature comparison by model Feature 24 port 16 Gb ESB SAN switch 24 port 16 Gb SAN switch 16 Gb SAN switch Number of licensed ports 24 24 12 Number of SFP included 0 2 x 16 Gb SFP 0 Full fabric Included Included Included Access Gateway Included Included Included Advanced zoning Included Included Included Enhanced Group Management Included Include...

Page 4: ...m of one upgrade of each type one Upgrade 1 and one Upgrade 2 is supported per one switch module Upgrade 1 and Upgrade 2 can be applied independently of each other Table 5 Ports on Demand upgrades Ports on Demand upgrade Total number of port licenses 24 port 16 Gb ESB SAN switch 24 port 16 Gb SAN switch 12 port 16 Gb SAN switch Included with base 24 24 12 Upgrade 1 88Y6382 only adds 12 port licens...

Page 5: ...roblems reducing fabric deployment and diagnostic times Brocade Fabric Vision Technology offers innovative diagnostic monitoring and management capabilities to help administrators avoid problems maximize application performance and reduce operational costs A building block for virtualized private cloud storage The FC5022 16 Gb Switch supports multi tenancy in cloud environments through VM aware en...

Page 6: ... to form a single logical ISL with a speed of up to 128 Gbps 256 Gbps full duplex for optimal bandwidth utilization automatic path failover and load balancing Fabric OS FOS version 7 0 x or higher which delivers distributed intelligence throughout the network and enables a wide range of value added applications such as Advanced Web Tools and Advanced Fabric Services on certain models Supports up t...

Page 7: ...ynamic Fabric Provisioning DFP Dynamic Path Selection DPS Enhanced BB credit recovery FDMI Frame Redirection Frame based Trunking FSPF IPoFC Management Server NPIV NTP v3 Port Fencing Reliable Commit Service RCS Simple Name Server SNS Software management HTTPS SNMP v1 v3 FE MIB FC Management MIB SSH Auditing Syslog APM Network Advisor base edition standard ProPlus or Enterprise optional license Co...

Page 8: ...etwork Advisor Server Application Optimization Allows VM QoS authentication and monitoring from SAN through adapter to VM and associated virtualized application The 24 port ESB model part number 90Y9356 is a fully enabled switch with a complete set of licensed features that maximizes performance ensures availability and simplifies management for the most demanding applications and expanding virtua...

Page 9: ...S 479 2011 FC FS 2 ANSI INCITS 424 2006 includes the following FC FS INCITS 373 2003 FC LS INCITS 433 2007 FC BB 3 INCITS 414 2006 includes the following FC BB 2 INCITS 372 2003 FC SB 3 INCITS 374 2003 replaces FC SB ANSI X3 271 1996 FC SB 2 INCITS 374 2001 RFC 2625 IP and ARP Over FC RFC 2837 Fabric Element MIB MIB FA INCITS TR 32 2003 FCP 2 INCITS 350 2003 replaces FCP ANSI X3 269 1996 SNIA Stor...

Page 10: ...patibility Description Part number Enterprise Chassis with CMM Enterprise Chassis with CMM2 Carrier grade Chassis with CMM2 Lenovo Flex System FC5022 16Gb SAN Scalable Switch 88Y6374 Yes Yes Yes Lenovo Flex System FC5022 24 port 16Gb SAN Scalable Switch 00Y3324 Yes Yes Yes Lenovo Flex System FC5022 24 port 16Gb ESB SAN Scalable Switch 90Y9356 Yes Yes Yes The connections between the 2 port adapters...

Page 11: ...he connections between the 4 port FC adapters that are installed in the compute nodes and the switch bays in the chassis are shown in Figure 4 Figure 4 Logical layout of the interconnects between the FC5054 4 port adapters and I O modules Lenovo Flex System FC5022 16Gb SAN Scalable Switches 11 ...

Page 12: ...e 7 Adapter to I O bay correspondence I O adapter slot in the server Port on the adapter Corresponding I O module bay in the chassis Slot 1 Port 1 Module bay 1 Port 2 Module bay 2 Port 3 Module bay 1 Port 4 Module bay 2 Slot 2 Port 1 Module bay 3 Port 2 Module bay 4 Port 3 Module bay 3 Port 4 Module bay 4 Slot 3 full wide compute nodes only Port 1 Module bay 1 Port 2 Module bay 2 Port 3 Module bay...

Page 13: ...Y2386 EC23 Flex System FC5054 4 port 16Gb FC Adapter 95Y2391 EC2E Flex System FC5172 2 port 16Gb FC Adapter 69Y1942 A1BQ 8 Gb Fibre Channel Flex System FC3172 2 port 8Gb FC Adapter 69Y1938 A1BM Flex System FC3052 2 port 8Gb FC Adapter 95Y2375 A2N5 The adapters are installed in slots in each compute node Figure 5 shows the locations of the slots in the x240 Compute Node The positions of the adapter...

Page 14: ...ware The Error LED switch module error indicates that the switch module has failed the POST or detected an operational fault One mini USB RS 232 console port that provides an additional means to configure the switch module This mini USB style connector enables connection of a special serial cable cable is optional and it is not included with the switch see the part number information section for d...

Page 15: ...1310 nm single mode fiber cable 9 µ up to 25 km LC Management ports External 1 GbE management port UTP Category 5 5E and 6 up to 100 meters RJ 45 External RS 232 management port DB 9 to mini USB or RJ 45 to mini USB console cable comes with optional Management Serial Access Cable 90Y9338 Mini USB Warranty The FC5022 switches carry a 1 year customer replaceable unit CRU limited warranty When instal...

Page 16: ...s per EN60950 1 2001 IEC60950 1 2001 Canada CSA C22 2 No 950 or 60950 Germany TUV VDE IEC 950 EN 60950 TUV component report IEC60950 CB Report and Certificate FCC Title 47 CFR Part 15 Class A Canada ICES 003 Australia New Zealand C Tick AS NZS CISPR 22 2006 CE Mark EN55022 2006 A1 2007 and EN55024 1998 A1 2001 A2 2003 VCCI Class A Japan VCCI 2009 Korea s EMC with KCC marking previously MIC marking...

Page 17: ...he SAN fabric and simplifies management This configuration can be used in small medium and large SAN environments In this scenario the FC5022 external connection to the upstream SAN fabric is displayed as an N Port SAN fabric configuration such as zoning is performed on the upstream SAN switch instead of the FC5022 For more information refer to the Brocade Fabric OS Access Gateway Administrator s ...

Page 18: ...to the FC storage SAN fabric configuration including zoning is performed on the FC5022 For more information on how to configure and manage the FC5022 switch module refer to the Brocade Fabric OS Administrator s Guide and the Brocade Fabric OS Command Reference Manual Figure 9 Direct attached storage Lenovo Flex System FC5022 16Gb SAN Scalable Switches 18 ...

Page 19: ...nt Letter for the 16Gb SAN and 24 port ESB SAN switches http ibm com common ssi cgi bin ssialias infotype dd subtype ca htmlfid 897 ENUS112 053 US Announcement Letter for the 16Gb 24 port SAN switch http ibm com common ssi cgi bin ssialias infotype dd subtype ca htmlfid 897 ENUS112 139 US Announcement Letter for the Features on Demand upgrades http ibm com common ssi cgi bin ssialias infotype dd s...

Page 20: ...ntended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All inform...

Page 21: ...s is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Lenovo ServerProven Flex System The following terms are trademarks of other companies Other company product or service names may be trademarks or service marks of others Lenovo Flex System FC5022 16Gb SAN Scalable Switches 21 ...

Reviews: