24
D1012/D1024 Storage Enclosure rear panel LEDs
The rear panel layout of a 2U (D1024/D1012) Storage Enclosure is shown below. Using mini-SAS
(SFF-8088) external connectors, these Storage Enclosures support a 6-Gbps data rate for backend SAS
on page 27 for more information.
Figure 13
LEDs: D1012/D1024 Storage Enclosure — rear panel
LED No./Description
Color
State
Definition
1 — Power Supply
—
—
See
2 — Unit locator
White
Off
Blink
Normal operation.
Physically identifies the Storage Enclosure.
3 — OK to Remove
Blue
Off
Not implemented.
4 — Fault/Service Required
Amber
On
Blink
A fault is detected or a service action is required.
Hardware-controlled power-up.
5 — CRU OK
Green
On
Off
Blink
Storage Enclosure is operating normally.
Storage Enclosure is not OK.
System is booting.
6 — SAS In Port Status
Green
On
Off
Port is connected and the link is up.
Port is empty or link is down.
7 — SAS Out Port Status
Green
On
Off
Port is connected and the link is up.
Port is empty or link is down.
0
0
IN
OUT
0
0
IN
OUT
1
2
6
3
5
4
7
1