Updating firmware for blade servers operating as a single partition
If you are performing inband updates to firmware on blade servers operating as a single partition in a
scalable blade complex, updates made to the firmware on the primary blade server are also applied to the
secondary blade server.
You can obtain the firmware updates from http://www.ibm.com/support/ fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
Complete the following steps to update the firmware for the blade servers operating as a single partition in a
scalable blade complex:
1. Run the IMM firmware update package on the primary blade server.
2. Run the UEFI firmware update package on the primary blade server.
3. Run the FPGA firmware update package on the primary blade server.
4. Run the DSA preboot firmware update package the primary blade server.
5. Restart the scalable blade complex to activate the firmware.
The firmware updates that were made to the primary blade server are applied to the secondary blade server.
Updating firmware for each blade server independently
If you are updating firmware for blade servers that are operating as independent partitions in a scalable blade
complex or you are performing out-of-band updates to firmware for blade servers in a scalable blade
complex, updates must be applied to each system in the scalable complex independently.
You can obtain the firmware updates from http://www.ibm.com/support/ fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
Complete the following steps to update the firmware for the blade servers:
Note:
The blade servers in the scalable blade complex must be at the same firmware levels before they are
restarted.
1. Update the IMM firmware on the primary blade server. Then update the IMM firmware on the secondary
blade server.
2. Reset the IMM on the primary and secondary systems. Complete the following steps to reset the IMM
through the advanced management module web interface:
a. Click
Blade Tasks
➙
Power/Restart
.
b. Click the checkbox next to the blade servers to be reset.
c. Click
Available actions
➙
Restart Blade System Mgmt Processor
.
d. Click
Perform Action
.
3. Update the UEFI firmware on the primary blade server. Then update the UEFI firmware on the secondary
blade server.
4. Update the FPGA firmware on the primary blade server. Then update the FPGA firmware on the
secondary blade server.
5. Update the DSA preboot firmware on the primary blade server. Then update the DSA Preboot firmware
on the secondary blade server.
6. Restart both blade servers to activate the firmware
You can also use an Expect type script to automate advanced management module command-line interface
(CLI) commands for updating the firmware for both blade servers. Complete the following steps to use an
Expect type script:
.
31
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...