A diagnostic text message contains one of the following results:
Passed:
The test was completed without any errors.
Failed:
The test detected an error.
User Aborted:
You stopped the test before it was completed.
Not Applicable:
You attempted to test a device that is not present in the blade server.
Aborted:
The test could not proceed because of the blade server configuration.
Warning:
The test could not be run. There was no failure of the hardware that was being tested, but there
might be a hardware failure elsewhere, or another problem prevented the test from running. For example,
there might be a configuration problem, or the hardware might be missing or is not being recognized.
The result is followed by an error code or other additional information about the error.
DSA messages
Use this information to review the diagnostic error messages and resolve any errors that might occur in the
blade server.
If the diagnostic programs generate error codes that are not listed in the table, make sure that the latest level
of the UEFI code is installed. To download the latest firmware for the blade server, go to http://www.ibm.
com/supportportal/.
The following table describes the messages that the diagnostic programs might generate and suggested
actions to correct the detected problems. Follow the suggested actions in the order in which they are listed
in the action column. In the error codes,
x
can be any numeral or letter. However, if the three-digit number in
the central position of the code is 000, 195, or 197,
do not
replace a CRU or FRU. These numbers appearing
in the central position of the code have the following meanings:
000
The blade server passed the test. Do not replace a CRU or FRU.
195
The Esc key was pressed to end the test. Do not replace a CRU or FRU.
197
This is a warning error, but it does not indicate a hardware failure; do not replace a CRU or FRU. Take
the action that is indicated in the Action column, but
do not replace a CRU or a FRU
. See the description
for
Warning
in the section “Diagnostic text messages” on page 212 for more information.
Microprocessor test
Use this information to view microprocessor test error codes and resolve test errors.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
213
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...