Installing the 2-node Scalability card
Use this information to install the 2-node scalability card on a blade server.
To install the 2-node scalability card, complete the following steps:
Step 1. Before you begin, read “Safety” on page v and “Installation guidelines” on page 65.
Step 2. If the blade servers are installed in a BladeCenter chassis, remove them (see “Removing the blade
server from the BladeCenter chassis” on page 66 for instructions).
Step 3. If an optional expansion unit is installed, remove the expansion unit (see “Removing an expansion
unit” on page 96 for instructions).
Note:
Optional expansion units are not supported when a IBM MAX5 expansion blade is installed.
Step 4. Remove the covers for both blade servers (see “Removing the blade server cover” on page 71 for
instructions).
Step 5. Remove the 1-node speed burst cards (see “Installing the 1-node speed burst card” on page 82) or
scalability fillers from both blade servers, depending on which you have installed.To remove the
scalability filler, complete the following steps:
a. Using the 3/16" hex driver that comes with the scalability kit, loosen the nut that attaches the
filler to the blade server.
b. Lift the filler off of the blade server.
Step 6. Attach the scalability tray to the topmost blade server (see “Installing the scalability tray” on page
Step 7. Attach the blade server with the scalability tray to the bottom blade server.
Blade server
cover release
Blade server
cover release
Cover
Pins
a. Lower the topmost blade server so that the slots at the rear slide down onto the pins at the rear
of the bottom blade server, as shown in the illustration.
b. Pivot the topmost blade server to the closed position, as shown in the illustration, until it clicks
into place.
Step 8. Stand the blade servers upright on a clean, flat work surface, with the scalability connector on the
blade servers facing up.
.
Removing and replacing blade server components
85
Summary of Contents for BladeCenter HX5 1909
Page 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 16: ......
Page 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Page 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Page 311: ......
Page 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Page 313: ... 1P46W8208 ...