2. Make sure all the removed components are installed, and all the disconnected cables inside the server
are reconnected.
To install the top cover, complete the following steps:
Figure 80. Top cover installation
Step 1. Align the posts inside the top cover with the slots on the chassis.
Step 2. Hold the front of the server and slide the top cover toward the front server until it clicks into place.
After you install the top cover, complete the following steps:
1. Install the server into rack if necessary.
2. Reconnect power cords and all external cables.
3. Turn on the server (see
“Power on the server” on page 10
TPM card replacement (for Chinese Mainland only)
Use this information to remove and install the TPM card.
Remove the TPM card (for Chinese Mainland only)
Use this information to remove the TPM card.
Before you remove the TPM card, complete the following steps:
1. Read
“Installation Guidelines” on page 31
to ensure that you work safely.
2. Turn off the server. Disconnect the power cords and all external cables (see
).
3. If server is installed in a rack, remove the server from the rack.
4. Remove the top cover (see
“Remove the top cover” on page 86
).
5. Locate the TPM card connector on the system board (see
“System-board connectors” on page 16
).
To remove the TPM card, complete the following steps:
88
ThinkSystem SR150 Maintenance Manual
Summary of Contents for 7Y54
Page 1: ...ThinkSystem SR150 Maintenance Manual Machine Type 7Y54 ...
Page 8: ...vi ThinkSystem SR150 Maintenance Manual ...
Page 25: ...Chapter 2 Server components 17 ...
Page 38: ...30 ThinkSystem SR150 Maintenance Manual ...
Page 102: ...94 ThinkSystem SR150 Maintenance Manual ...
Page 128: ...120 ThinkSystem SR150 Maintenance Manual ...
Page 132: ...124 ThinkSystem SR150 Maintenance Manual ...
Page 137: ......
Page 138: ...Part Number SP47A31793 Printed in Chinese Mainland 1P P N SP47A31793 1PSP47A31793 ...