Figure 63. Removing a Torx T30 nut from the heat sink
Note:
Do not touch the gold contacts on the bottom of the processor.
Rotate the anti-tilt wire bail inwards.
Push the upper edge of the Torx T30 nut towards the center of the heat sink until it
disengages.
Remove the Torx T30 nut.
Attention:
Visually inspect the removed Torx T30 nut, if the nut is cracked or damaged, make sure
no debris or broken pieces are left inside the server.
After this task is completed
• Install a replacement unit. See
“Install a heat sink Torx T30 nut” on page 83
• If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install a heat sink Torx T30 nut
See this topic to learn how to install a PEEK (Polyether ether ketone) Torx T30 nut on the heat sink.
About this task
Note:
The heat sink, processor, and processor carrier for the system might be different from those shown in
the illustrations.
Watch the procedure.
A video of this procedure is available from the following link:
•
https://www.youtube.com/playlist?list=PLYV5R7hVcs-DV_Ja2E7l6T-lwN_IrnJRk
Procedure
Step 1. Install the Torx T30 nut.
.
Hardware replacement procedures
83
Summary of Contents for 7D8T
Page 1: ...ThinkEdge SE450 Maintenance Manual Machine Types 7D8T ...
Page 8: ...vi ThinkEdge SE450 Maintenance Manual ...
Page 22: ...14 ThinkEdge SE450 Maintenance Manual ...
Page 45: ...Server components Figure 17 Server components Chapter 2 Server components 37 ...
Page 184: ...176 ThinkEdge SE450 Maintenance Manual ...
Page 206: ...198 ThinkEdge SE450 Maintenance Manual ...
Page 210: ...202 ThinkEdge SE450 Maintenance Manual ...
Page 217: ......
Page 218: ......