A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
Step 1. If a bracket is installed on the PCIe adapter, remove the two screws and remove the bracket.
Step 2. Connect all cables to the adapter.
Step 3. Install the PCIe adapter.
Note:
Ensure that you observe the installation rules and sequence in “Technical rules for PCIe
adapters” in the
ThinkSystem SR250 V2 Setup Guide
.
Figure 86. PCIe adapter installation
a.
Lower the PCIe adapter into the server; then, firmly press it into the connector.
b.
Install the screw to secure the PCIe adapter.
After you finish
1. Install the top cover. See
“Install the top cover” on page 134
2. Complete the parts replacement. See
“Complete the parts replacement” on page 140
3. Configure the RAID array using the Setup utility configuration.
PCIe riser assembly replacement
Use this procedure to remove or install the PCIe riser assembly.
Remove the PCIe riser assembly
Use this information to remove the PCIe riser assembly.
About this task
Attention:
• Read the following section(s) to ensure that you work safely.
.
Hardware replacement procedures
99