If this warning message appears, complete the following steps:
1. Record each of the instructions of changing PMEM slot from XCC events.
2. Power off the system, and remove the PMEMs that are mentioned in the warning messages. It is
suggested to label these PMEMs to avoid confusion.
3. Install the PMEMs in the correct slot number indicated in the warning messages. Remove the labels to
avoid blocking airflow and cooling.
4. Complete replacement and power on the system. Make sure there is no similar warning messages in
XCC.
Note:
Do not perform any provisioning on PMEM to avoid data lost when the messages are still present in
XCC events.
After PMEMs are reconfigured, error messages and LEDs persist to indicate PMEMs are installed in
wrong slots
AC the system or restart XCC to solve this problem.
Cannot create goal successfully when installing PMEMs to the system for the first time
When seeing ones of the following messages:
• ERROR: Cannot retrieve memory resources info
• ERROR: One or more PMEM modules do not have PCD data. A platform reboot is recommended to
restore valid PCD data.
Complete the following steps to solve the problem.
1. If the PMEMs have been installed in another system with stored data, perform the following steps to
erase the data.
a. Based on the original population order, install the PMEMs to the original system where they were
installed previously, and back up the data from the PMEMs to other storage devices.
b. Disable PMEM security with one of the following options:
•
LXPM V3
Go to
UEFI Setup
➙
System Settings
➙
Intel Optane PMEMs
➙
Security
➙
Press to Disable
Security
, and input passphrase to disable security.
•
Setup Utility
Go to
System Configuration and Boot Management
➙
System Settings
➙
Intel Optane
PMEMs
➙
Security
➙
Press to Disable Security
, and input passphrase to disable security.
c. Delete namespaces with command corresponding to the operating system that is installed:
•
Linux
command:
ndctl destroy-namespace all -f
•
Windows
Powershell command
Get-PmemDisk | Remove-PmemDisk
d. Clear Platform Configuration Data (PCD) and Namespace Label Storage Area (LSA) with the following
ipmctl command (for both Linux and Windows).
ipmctl delete -pcd
Notes:
See the following links to learn how to download and use impctl in different operating
systems:
• Windows: https://datacentersupport.lenovo.com/us/en/videos/YTV101407
• Linux: https://datacentersupport.lenovo.com/us/en/solutions/HT508642
240
ThinkSystem SR850 V2 Maintenance Manual
Summary of Contents for 7D31
Page 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Page 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Page 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Page 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Page 71: ...Chapter 3 Internal cable routing 63 ...
Page 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Page 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Page 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Page 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Page 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Page 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Page 273: ......
Page 274: ......