Drive tray
assembly
Release
latch
1.8-inch
filler panel
c. Insert the drive into the drive tray with the label side of the drive facing up and push the drive
tray into the drive bay until it clicks into place and is seated firmly.
d. Rotate the drive tray handle to the closed position and slide the release latch to the left to
secure the drive tray handle in place.
e. Replace the filler panel (EMC filler panel).
Step 6. Check the drive status LED to verify that the drive is operating correctly. If the amber drive status
LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green drive activity
LED is flashing, the drive is being accessed.
Note:
If the server is configured for RAID operation through a ServeRAID adapter, you might have
to reconfigure your disk arrays after you install drives. See the ServeRAID adapter documentation
for additional information about RAID operation and complete instructions for using the ServeRAID
adapter.
Step 7. If you are installing additional hot-swap drives, do so now.
Step 8. Complete the additional steps in “Instructions for Business Partners” on page 43.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation” on
page 117.
Installing the half-length and full-length I/O books
Use this information for an overview of the supported I/O books.
The server provides up to twelve PCIe Gen3 adapter slots using the supported I/O books. The server
supports an optional half-length I/O book and an optional full-length I/O book. You install both I/O books in
78
System x3850 X6 and x3950 X6 Installation and Service Guide
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......