To backup the system configuration of the IBM server to a file, use the
ASU save
<filename>
command, where
<filename>
is the complete path name of the file where the configuration is to be
saved.
•
Backup Features on Demand (FoD) keys
To backup the Features on Demand (FoD) keys of the IBM server:
– To export the FoD inventory information for the IBM server, use the
ASU fodcfg reportkey
command.
– To export the FoD keys for the IBM server, use the
ASU fodcfg exportkey
command.
•
Backup vital product data (VPD)
Notes:
– Make sure that you are using the latest version of the IBM ASU tool.
– For an IBM System x3950 X6 8-socket system, the following procedure must be performed twice,
once for each of the standard I/O books in the system.
To backup the VPD data for the IBM server:
– To save the VPD information for an IBM System x3850 X6 4–socket system, complete the
following steps. Save the files in secure location, as the values they contain will need to be re-
entered after installing the new Lenovo standard I/O book.
a. To save the system VPD information into a file, run the ASU command:
asu64 show SYSTEM_PROD_DATA --host
<IMM IP>
--user
<IMM userid>
--password
<IMM
password>
>
<serial>
_system.txt
where:
<IMM IP>
is the IMM IP address
<IMM userid>
is the IMM user name
<IMM password>
is the IMM password
<serial>
is the serial number of the standard I/O book (allows each data file to be identified)
b. To save the system component VPD information into a file, run the ASU command:
asu64 show VPD --host
<IMM IP>
--user
<IMM userid>
--password
<IMM password>
>
<serial>
_component.txt
where:
<IMM IP>
is the IMM IP address
<IMM userid>
is the IMM user name
<IMM password>
is the IMM password
<serial>
is the serial number of the standard I/O book (allows each data file to be identified)
– To save the VPD information for an IBM System x3950 X6 8–socket system, complete the
following procedures. Save the files in secure location, as the values they contain will need to be
re-entered after installing the new Lenovo standard I/O books.
– To save the system VPD information for node 1 of an IBM System x3950 X6 8–socket system,
complete the following steps:
a. To save the system VPD information for node 1 into a file, run the ASU command:
asu64 show SYSTEM_PROD_DATA --host
<IMM IP>
--user
<IMM userid>
--password
<IMM
password>
>
<serial>
_Node1_system.txt
where:
<IMM IP>
is the IMM IP address
.
Removing and replacing components
313
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......