Release latch
Handle
Handle
Filler panel
.
Step 4. Rotate the handle all the way up and push it into the server until it locks in place.
Step 5. Reconnect any external cables to the adapters, if you removed any earlier.
Step 6. Press the
Power button
on the I/O book to turn the power onto the adapter slots. The Green LED
will begin flashing. When the Green LED stop flashing, the adapter is ready for use.
Removing the full-length I/O book
This information provides instructions for removing the full-length I/O book.
To remove the full-length I/O book, complete the following steps:
Step 1. Before you begin, read “Safety” on page v and “Installation guidelines” on page 44 .
Step 2. The full-length I/O book is hot-swappable if no adapters are installed in the I/O book. If adapters
are installed in the I/O book, you must first press the
Power button
on the I/O book and power-off
all three PCIe adapter slots before you remove the I/O book from the server. The slots LED lights
will be off when the slots are off-line.
Step 3. Remove any external cables that are attached to the adapters.
Step 4. Press the blue release latch downward; then, rotate the handle all the way down and slide the I/O
book out of the server.
.
Removing and replacing components
235
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......