Step 3. From the Setup utility main menu, select
Boot Manager
.
Step 4. Select
Add Boot Option
; then, select
Generic Boot Option
and
Embedded Hypervisor
. Press
Enter, and then press Esc.
Step 5. Select
Change Boot Order
and then select
Change the order
. Use the Up arrow and Down Arrow
keys to select
Embedded Hypervisor
and use the plus (+) and minus (-) keys to move Embedded
Hypervisor in the boot order. When
Embedded Hypervisor
is in the correct location in the boot
order, press Enter. Select
Commit Changes
and press Enter.
Step 6. Select
Save Settings
and then select
Exit Setup
.
If the embedded hypervisor flash device image becomes corrupted, you can download the image from
www3.lenovo.com/us/en/data-center/software/c/software
For additional information and instructions, see the
VMware vSphere Installation and Setup Guide
vSphere Installation and Setup Guide.
Configuring the Ethernet controller
This topic provides information about configuring the Ethernet controllers.
The Ethernet controller provides an interface for connecting to a 1 Gbps or 10 Gbps network and provides
full-duplex (FDX) capability, which enables simultaneous transmission and reception of data on the network.
If the Ethernet ports support auto-negotiation, the controller detects the data-transfer rate (100BASE-T,
1000BASE-T, or 10GBASE-T) and duplex mode (full-duplex or half-duplex) of the network and automatically
operate at that rate and mode.
You do not have to set any jumpers or configure the controller. However, you must install a device driver to
enable the operating system to address the controller. For device drivers and information about configuring
the Ethernet controller, go to
http://datacentersupport.lenovo.com/
.
Enabling Features on Demand Ethernet software
This topic provides information about enabling Features on Demand Ethernet software.
You can activate the Features on Demand (FoD) software upgrade key for Fibre Channel over Ethernet
(FCoE) and
i
SCSI storage protocols that is integrated in the integrated management module. For more
information and instructions for activating the Features on Demand Ethernet software key, see the
Features
on Demand User’s Guide
https://fod.lenovo.com/lkms/angular/app/pages/index.htm#/help
. To download the
document and or more information about Features on Demand, go to
, log in, and
click
Help
.
Enabling Features on Demand RAID software
This topic provides information about enabling Features on Demand RAID software.
Integrated into the integrated management module is a Features on Demand RAID software upgrade key that
you can activate to get support for RAID levels 5 and 50 or 6 and 60 (depending on the Features on Demand
key). For more information and instructions for activating the Feature On Demand RAID software key, see the
Features on Demand User’s Guide
https://fod.lenovo.com/lkms/angular/app/pages/index.htm#/help
. To
download the document or to find more information about Features on Demand, go to
, log in, and click
Help
.
Configuration information and instructions
139
Summary of Contents for 6241
Page 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Page 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Page 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Page 1989: ......
Page 1990: ......