NOTICE

The humidistat must be installed in accordance with
all local and national standards.

Installation, adjustments, alterations, service and
maintenance must be performed by a qualified ser­
vice technician.

Product Description 

The HC Digital Automatic Humidistat is a programmable
control for HCSteam residential humidifiers. While the HC
Digital Automatic Humidistat may be used for control of
other humidification or dehumidification appliances, its op­
erating modes are designed for modulating control of the
HCSteam electrode steam humidifiers.

When properly installed and configured, the HC Digital Au­
tomatic Humidistat will use information from the environ­
ment including Relative Humidity, Outdoor Temperature
and Home Construction to determine the Ideal Humidity
and the Optimum Humidifier Output.

The HC Digital Automatic Humidistat includes an Indoor
Temperature Sensor, Indoor Humidity Sensor and Control
Unit.  A separate Outdoor Sensor is supplied.

Humidistat Dimensions

Prg

°

C/

°

F

Set

Prg

°

C/

°

F

Set

3 1

/2

” (86 mm)

5 1/4” (135 mm)

1-1/2”

(36 mm)

Disposal

The product is made from metal and plastic
parts. All parts must be disposed of accord­
ing to the local standards on waste disposal.

Summary of Contents for Y3760

Page 1: ...al Automatic Humidistat is a programmable control for HCSteam residential humidifiers While the HC Digital Automatic Humidistat may be used for control of other humidification or dehumidification appliances its op erating modes are designed for modulating control of the HCSteam electrode steam humidifiers When properly installed and configured the HC Digital Au tomatic Humidistat will use informat...

Page 2: ...al block by squeezing the clips on the terminal cover 5 Make the necessary connections and run the wires through the hole in the middle of the base Separate the connection and control cables from the relay cables The diagrams are shown under Electrical Con nections Page 3 NOTICE Make sure all connections are complete before re connecting the flat cable and front part of the humi distat For the pur...

Page 3: ...ifier for ON OFF Operation IMPORTANT Be sure the connections are made as de scribed in the following and as shown in figure 3 1 Connect HCSteam Humidifier terminal 24V to HC Dig ital Automatic Humidistat terminal 6 G 2 Connect HCSteam Humidifier terminal GND to HC Digital Automatic Humidistat terminal 5 G0 3 Connect HCSteam Humidifier terminal GND to HC Digital Automatic Humidistat terminal 1 4 Co...

Page 4: ... above expected snow line S Maximum conductor length of the Outdoor Tempera ture Sensor is 100 feet 30m of standard thermostat cable twisted pair not required S Connect Outdoor Temperature Sensor to terminals 8 and 9 Table 2 Outdoor Sensor Temperature Resistance Range Temperature ºF ºC Resistance Value KOHM Temperature ºF ºC Resistance Value KOHM Maximum Standard Minimum Maximum Standard Minimum 4...

Page 5: ...night for the set time To change or reset the timer use the UP and DOWN buttons to increase or decrease the time Press a second time to exit and return to the main menu If sleep mode is already active pressing the button shows the time remaining on the timer E g if the humidistat is in Night mode moon symbol on from time band pressing this button activates daytime mode moon symbol off for the set ...

Page 6: ...e set points are used the night settings are only used when the NIGHT button is pressed manually changing mode Auto humidity control In addition to the modes featured by the control algorithms the humidity can be controlled automatically based on the reading of the outside temperature sensor The aim of this type of control is to simplify the setting of the HC Digital Automatic Humidistat changing ...

Page 7: ... operating mode the links between the various basic and advanced levels are specified S if level 1 is active the level 2 parameters are not used but rather replaced by the default values or by the link value with the level 1 parameters S the level 2 parameters are effectively used when level 2 is activated Humidity control This type of control is used to send a start signal to a hu midifier or deh...

Page 8: ...OFF the mode is disabled Setting one of the levels in the table the controller independently sets a humidity set point in relation to the outside temperature OFF 1H to 7H OFF CAL Int Inside temperature calibration digital sensor or NTC Within a maximum of 10 C 10 to 10 0 0 C CAL ESt Outside temperature calibration NTC sensor Within a maximum of 10 C 10 to 10 0 0 C CAL HUn Digital humidity sensor c...

Page 9: ...tact closing current 3 to 5 mA Outside temperature sensor connection with standard sensor 10K 25 C β 3435 Maximum length 100 30 m min cable cross section 20 AWG 0 5 mm2 Digital input connection Maximum length 33 10 m min cable cross section 20 AWG 0 5 mm2 Analog output connection Maximum length 33 10 m min cable cross section 20 AWG 0 5 mm2 Relay output connections Maximum length 100 30 m cable cr...

Page 10: ...Page 10 506808 01 06 11 070220641 Rel 1 0 June 2011 ...