background image

Page 10

E1 — Module Data Sheet 

COMPONENT MATERIALS

265 Wp

Cells per module

60

Cell type

Mono crystalline

Cell dimensions

6.14 in. x 6.14 in.

Front

Tempered glass

(EN 12150)

Frame

Clear anodized

aluminum

Weight

47 lbs.

SYSTEM INTEGRATION PARAMETERS

Maximum system voltage SC II

1000V

Maximum system voltage USA NEC

600V

Maximum reverse currents

16A

Number of bypass diodes

3

UL Design Loads

Two rail system

113 psf downward,

64 psf upward

UL Design Loads

Three rail system

170 psf downward,

64 psf upward

IEC Design Loads

Two rail system

113 psf downward,

50 psf upward

THERMAL CHARACTERISTICS

265 Wp

NOCT

115

F

TCI

SC

0.004%/K

TC

VOC

–0.30%/K

TCP

MPP

–0.45%/K

Operating Temp.

–40

F to 185

F

ADDITIONAL DATA

265 Wp

Power Tolerance

0 Wp / +5 Wp

J

Box

IP65

Connector

MC4

Module ef’iciency

15.81%

Fire rating UL (790)

Class C

PERFORMANCE

Performance

Under

1

Standard Testing

Conditions

2

 Performance At 800 W/M

2

,

Normal Operating Cell

Temperature (NOCT),

AM 1.5

Maximum Power

P

max

265 Wp

187.6 Wp

Open Circuit

Voltage

V

oc

38.1V

34.3V

Maximum Power

Point Voltage

V

mpp

31.9V

28.7V

Short Circuit

Current

I

sc

8.82A

7.12A

Maximum Power

Point Current

I

mpp

8.33A

6.66A

1

 Standard Testing Conditions at 1000W/m

2

, 25

C, AM 1.5

2

 Minor reduction in ef’i

Summary of Contents for SunSource

Page 1: ...ractive solar photovoltaic system generally requires a permit from the local authority having jurisdiction AHJ This document provides a typical format for a residential permit application to install a...

Page 2: ...C power is connected directly to an Enphase microinventer mounted below each module 240VAC power from the microinventer passes through a renewable energy credit meter next through a disconnect switch...

Page 3: ...1 0 SOUTH FACING ROOF 3 18 KW PV ARRAY DETAILS S 12 SW 265 solar PV AC modules in one AC circuit S 12 Enphase M215 60 2LL S22 240 S 90MPH designed wind speed and exposure category B S Composition shi...

Page 4: ...Page 4 B1 Wiring Diagram Figure 1 SunSource Home Energy System Electrical Layout...

Page 5: ...Page 5 B1 Alternate Wiring Diagram...

Page 6: ...Conduit de rate factor 1 S Maximum wire temperature allowed 167 F 75 C S Selected wire size 10 AWG S Insulation type THHN THWNN 2 Specified wire ampacity 30 45 amps 3 Conduit size S Conduit specified...

Page 7: ...Page 7 C1 PVWatts Calculations...

Page 8: ...Page 8 C1 PVWatts Calculations continued...

Page 9: ...HVAC DISCONNECT SWITCH USED ON UNIT CB10 PLASTIC COVER USED ON UNIT CB40 PLASTIC COVER USED NEXT TO CIRCUIT BREAKER IN MAIN PANEL SOURCE CIRCUIT DISCONNECT FOR SOLAR DISCONNECT BOTH POWER SOURCES BEFO...

Page 10: ...Loads Two rail system 113 psf downward 50 psf upward THERMAL CHARACTERISTICS 265 Wp NOCT 115 F TCISC 0 004 K TCVOC 0 30 K TCPMPP 0 45 K Operating Temp 40 F to 185 F ADDITIONAL DATA 265 Wp Power Toler...

Page 11: ...Page 11 E1 Module Data Sheet continued DIMENSIONS INCHES MM 11 3 8 41 3 8 66 1 1 4 39 3 8 1000 37 1 2 4 1 4 952 2 1 2 1676 1051 289 1 3 8 35 108 1 1 4 32 5 8 16...

Page 12: ...oups of three it creates a balanced 3 phase system If systems are installed in something other than multiples of three a small imbalance will be created across the phases The maximum output of each in...

Page 13: ...V 183 229V 240V 211 264V Extended Voltage Range 208V 179 232V 240V 206 269V Nominal Frequency Range 60 0 59 3 60 5 Hz 60 0 59 3 60 5 Hz Extended Frequency Range 60 0 59 2 60 6 Hz 60 0 59 2 60 6 Hz Pow...

Page 14: ...nels are rated for coastal conditions in Florida Install the flashing below the upper shingle to allow water to run around the raised penetration point Seal the penetration and lag screws with appropr...

Page 15: ...Page 15 QUICK MOUNT PV CONTINUED...

Reviews: