background image

USER’S INFORMATION 

MANUAL

©2017 Lennox Industries Inc. 
Dallas, Texas, USA

507650-01

10/2017

SL280UHNV

SERIES

 WARNING

Improper installation, adjustment, alteration, service 

or maintenance can cause property damage, personal 

injury or loss of life. Installation and service must  be 

performed by a licensed professional HVAC installer or 

equivalent, service agency, or the gas supplier.

 WARNING

FIRE OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.
Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

•   Do not try to light any appliance.
•   Do not touch any electrical switch; do not
•  use any phone in your building.
•   Immediately call your gas supplier from a
•  neighbor’s phone. Follow the gas supplier’s
•  instructions.
•   If you cannot reach your gas supplier, call
•  the fire department.

WHAT TO DO IF YOU SMELL GAS:

Summary of Contents for SL280UHNV Series

Page 1: ...lure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other a...

Page 2: ...s is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible the water supply to...

Page 3: ...azard The exhaust vent for this furnace must be leak free and must be securely connected to the furnace flue collar at all times For your safety and to fulfill the terms of the limited warranty a lice...

Page 4: ...LET SUPPLY PRESSURE TAP GAS VALVE SHOWN IN THE ON POSITION FIGURE 3 9 Replace the upper access panel 10 Turn on all electrical power to to the unit 11 Set the thermostat to desired setting NOTE When u...

Page 5: ...y sound and without holes corrosion or blockage The vent connector must be correctly posi tioned and sloped upward The vent connector must be physically sound without holes or excessive corrosion Insp...

Page 6: ...cable 3 Inspect all gas pipe and connections for leaks 4 Check the cleanliness of filters and change if necessary monthly 5 Check the condition and cleanliness of burners and heat exchanger and clean...

Page 7: ...t Parts Upper access panel Blower access panel Top Cap Control Panel Parts Transformer SureLight integrated control Door interlock switch Circuit Breaker Blower Parts Blower wheel Motor Blower housing...

Reviews: