Page 22
TABLE 5
MANUFACTURER'S NUMBERS - NO TENSIONER
DRIVE NO.
DRIVE COMPONENTS
ADJUSTABLE SHEAVE
FIXED SHEAVE
BELT
BROWNING NO.
OEM PART NO.
BROWNING NO.
OEM PART NO.
BROWNING NO.
OEM PART NO.
1
1VP34x7/8
31K6901
AK61x1
100244-20
AX54
100245-25
2
1VP40x7/8
79J0301
AK59x1
31K6801
AX55
100245-26
3
1VP34x7/8
31K6901
AK46x1
100244-17
AX52
100245-33
4
1VP44x7/8
53J9601
AK74x1
100244-21
AX58
100245-34
5
1VP50x7/8
P-8-2187
AK69x1
37L4701
AX58
100245-34
6
1VP50x7/8
P-8-2187
AK64x1
12L2501
AX57
100245-28
7
1VP44x1-1/8
36C0701
AK74x1
100244-21
AX58
100245-34
8
1VP50x1-1/8
P-8-1977
AK69x1
37L4701
AX58
100245-34
9
1VP50x1-1/8
P-8-1977
AK64x1
12L2501
AX57
100245-28
10
1VP50x1-1/8
P-8-1977
BK77x1
49K4001
BX59
59A5001
11
1VP50x1-1/8
P-8-1977
BK67x1
100244-24
BX57
78L5301
12
1VP50x1-1/8
P-8-1977
BK62x1
100244-23
BX56
100245-11
TABLE 6
MANUFACTURER'S NUMBERS - WITH TENSIONER
DRIVE NO.
DRIVE COMPONENTS
ADJUSTABLE SHEAVE
FIXED SHEAVE
BELT
BROWNING NO.
OEM PART NO.
BROWNING NO
OEM PART NO.
BROWNING NO.
OEM PART NO.
1T
1VP44X7/8
P81488
BK95X1
79J2701
BX68
88K3401
2T
1VP50X7/8
P82187
BK90X1
P89659
BX68
88K3401
3T
1VP56X7/8
P81494
BK85X1
49K4101
BX69
10024551
4T
1VP44X7/8
P81488
BK77X1
49K4001
BK66
88K3301
5T
1VP56X7/8
P81494
BK85X1
49K4101
BX69
10024551
6T
1VP50X7/8
P82187
BK67X1
10024424
BX65
10024508
7T
1VP44X11/8
10023907
BK77X1
49K4001
BX68
88K3401
8T
1VP56X11/8
P81492
BK85X1
49K4101
BX70
31K9601
9T
1VP50X11/8
P81977
BK67X1
10024424
BX66
88K3301
10T
1VP50X11/8
P81977
BK77X1
49K4001
BX68
88K3401
11T
1VP50X11/8
P81977
BK67X1
10024424
BX66
88K3301
12T
1VP50X11/8
P81977
BK62X1
10024423
BX66
88K3301
Cooling Start-Up
IMPORTANT-The crankcase heater must be energized
for 24 hours before attempting to start compressor. Set
thermostat so there is no demand to prevent
compressors from cycling. Apply power to unit.
A-Start-Up
Supply Air Inverter Units - Refer to the Belt Drive Supply
Air Inverter Start-Up or Direct Drive Variable Blower
section.
1- Initiate first and second stage cooling demands
according to instructions provided with thermostat.
2- First-stage thermostat demand will energize
compressor 1. Second-stage thermostat demand will
energize compressor 2. On units with an economizer,
when outdoor air is acceptable, a first-stage demand
will energize the economizer; a second-stage
demand will energize compressor 1.
3- Ultra high efficiency units have a tandem refrigerant
ciruit. High efficiency units have two typical circuits.
See figure 25, 26, 27, or 28.
4- Each refrigerant circuit is charged with R410A
refrigerant. See unit rating plate for correct
amount of charge.
5- Refer to Cooling Operation and Adjustment section for
proper method to check refrigerant charge.