Smart Hub Parameters
Parameter
Description
Stage Delay
Timers
(First)
Enabled (default) setting: When enabled all stage delay
timers (stages 2 through 6) are enabled and will serve
to bring on additional stage(s) of cooling or heating on a
timed basis (default 20 minutes)
Disabled setting: All stages delay timers are disabled.
Heat/cool stages are changed based on temperature
The second-stage delay timer (when stage timers is
Enabled) is used for both HEATING and COOLING.
Stage Delay
Timers
(2 through 6)
Second through Sixth Stage Delay timer (where
applicable) - If staged delay timers are “Enabled”, the
default is 20 minutes but can be programmed from 5 to
120 minutes in 5-minute increments. If the first stage fails
to advance the ambient temperature toward the set point
by 1.0°F (0.56°C) in the programmed delay time, then the
second stage is activated.
Stage Differentials
(1 through 6)
Number of stages in thermostat is dependent on
equipment that is installed.
Temp Reading
Calibration
Range is -5.0 to 5.0°F (-2.78 to -2.78°C). Default is 0.0°F
(-0.0°C).
If it is determine that the actual temperature being
detected at the thermostat is off based on independent
readings using other ambient temperature reading
devices, the display can be adjusted using this setting.
Temperature
Control Mode
Options are Normal and Comfort. Default is Normal. The
Feels-Like feature factors in the outdoor temperature
and indoor humidity for a more accurate control of the
temperature in the home. Either an outdoor temperature
sensor is used or Internet Weather is enabled for this
feature to operate. Modifying this setting here will also
change the feature status on the user settings screen.
Normal - This setting cools or heats the home to the
desired temperature setting (feels-like) is OFF.
Comfort - This setting cools or heats the home to the
desired temperature setting (Feels Like) is ON. When set
to ON, other parameters are modified to optimal settings
for this feature. Those setting changes will be listed on-
screen when Comfort is enabled.
Smart Hub Parameters
Parameter
Description
Wall Insulation
Options are poor, average and good. Default is average.
Air Handler
Table 8. Air Handler Parameters
Parameter
Description
About
Provides information concerning unit code, language
support, equipment type name, unit model number,
unit serial number, unit nominal capacity, number
of heating states, heating capacity by stage, indoor
blower CFM range, control software revision, control
model number, control serial number, control hardware
revision, discharge air temp sensor, outdoor air temp
sensor, protocol revision number, device product level,
factory installed transformer, 24VAC average power
consumption, 24VAC peak power consumption, line
voltage average power consumption, line voltage peak
power consumption, compatible devices list, applicable
code memory size, and micro-controller part number..
Reset Air Handler
Any installer modifications under the air handler tab
will be reset back to the factory defaults if the reset air
handler option is used.