XP16 − 2 to 5 Ton Heat Pump
INSTALLATION CLEARANCES
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
See
NOTES
See NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on one
of the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. (914 mm).
Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. (610 mm) must be maintained between two
units.
48 in. (1219 mm) clearance required on top of unit.
See
NOTES
See NOTES
Control
Box
OUTDOOR SOUND DATA
1
U it
Octave Band Sound Power Levels dBA, re 10
−12
Watts
1
Sound
R ti
1
Unit
Model No.
Center Frequency − HZ
Rating
Number
Model No.
63
125
250
500
1000
2000
4000
8000
Number
(dB)
XP16-024
79.0
72.0
70.0
69.5
68.5
63.5
58.0
56.5
74
XP16-036
80.5
70.5
71.5
71.0
68.5
63.5
58.5
53.5
76
XP16-048
81.0
72.5
71.5
73.0
70.5
66.0
60.5
58.5
76
XP16-060
80.5
72.5
73.5
77.5
72.5
67.0
62.5
58.5
78
NOTE − the octave sound power data does not include tonal correction.
1
Tested according to ARI Standard 270-95 test conditions.
FIELD WIRING
DISCONNECT
SWITCH
(By Others)
OPTIONAL
OUTDOOR
THERMOSTAT
A Two Wire Power (see Electrical Data)
B Two or Three Wire Power (size to heater capacity)
C Twelve Wire Low Voltage 18 ga. minimum
Fourteen Wire Low Voltage with Optional Outdoor Thermostat
D Eight Wire Low Voltage 18 ga. minimum
Ten Wire Low Voltage with Optional Outdoor Thermostat
Field Wiring Not Furnished
All wiring must conform to NEC or CEC and local electrical codes.
LENNOX
INDOOR UNIT
OPTIONAL
ELECTRIC
HEAT
THERMOSTAT
(Optional)
LENNOX
OUTDOOR
UNIT
DISCONNECT
SWITCH
(By Others)
A
B
C
D