Page 2

506316−0

1 11/16

ACBX32CM Upflow  and  Downflow  Unit

  Dimensions

 

  Inches

  (mm)

ACBX32CM Model Dimensions (for Upflow, Downflow, 

  LH and RH Horizontal  Applications)

Dimension

−136

−148/−160

inches

mm

inches

mm

A

51

1295

58-1/2

1486

B

21-1/4

540

21-1/4

540

C

22-5/8

575

24-5/8

625

D

19-3/4

502

19-3/4

502

E

21

533

23

584

F

20

508

20

508

G

26-3/8

670

27-7/8

708

H

24-5/8

625

30-5/8

778

OPTIONAL

ELECTRIC

HEAT

(FIELD−

INSTALLED)

Air Flow

LIQUID

LINE

SUCTION

LINE

SUPPLY

AIR OPENING

Return Air

FILTER

LOW VOLTAGE

INLETS (TOP AND RIGHT

SIDE)

Return Air

Top View

w

e

i

V

 

e

d

i

S

w

e

i

V

 t

n

o

r

F

Blower

PIPING PLATE DETAIL

(FOR UPFLOW AND DOWNFLOW POSITIONS)

A

C

B

11-1/16

(281)

D

F

E

LIQUID LINE

SUCTION LINE
CONDENSATE

DRAINS (2)

(HORIZONTAL)

Coil

3/4

(19)

3/4

(19)

5/8

(16)

5/8

(16)

1

(25)

5/8

(16)

1-3/4 (44)

2

(51)

1-1/8 (29)

4-3/8 (111)

2-3/4

(70)

5-3/8

(137)

3-1/2 (89)

OPTIONAL

ELECTRIC

 HEAT (FIELD

INSTALLED)

Air Flow

LIQUID

LINE

SUCTION

LINE

Return

Air Opening

Supply Air

FILTER

Supply Air

Top View

Front View

Side View

Blower

A

B

C

11-1/16 (281)

F

D

E

Coil

5/8

(16)

5/8

(16)

5/8

(16)

5/8 (16)

5/8

(16)

LOW VOLTAGE

(RIGHT SIDE)

LINE VOLTAGE

(LEFT SIDE)

Downflow

 

Position

(KIT NUMBER 83M57 

(LB−909844A)

 REQUIRED TO CONVERT

UNIT TO DOWNFLOW APPLICATIONS.)

1 (25)

Upflow Position

CONDENSATE

DRAINS (2)

(UPFLOW AND

DOWNFLOW)

FILTER

ACCESS

FILTER

ACCESS

H

G

H

G

LINE VOLTAGE

INLETS (TOP

AND LEFT SIDE)

5/8

(16)

5/8 (16)

Summary of Contents for ACBX32CM

Page 1: ...LLATION INSTRUCTIONS ACBX32CM Units AIR HANDLER 506316 01 11 16 Table of Contents ACBX32CM Upflow Downflow Unit Dimensions 2 ACBX32CM Horizontal LH RH Unit Dimensions 3 3 n o i t a m r o f n I l a r e...

Page 2: ...o r F Blower PIPING PLATE DETAIL FOR UPFLOW AND DOWNFLOW POSITIONS A C B 11 1 16 281 D F E LIQUID LINE SUCTION LINE CONDENSATE DRAINS 2 HORIZONTAL Coil 3 4 19 3 4 19 5 8 16 5 8 16 1 25 5 8 16 1 3 4 4...

Page 3: ...1 25 1 25 11 1 16 281 PIPING PLATE DETAIL LIQUID LINE SUCTION LINE 2 51 1 1 8 29 5 3 8 137 4 3 8 111 PIPING PLATE DETAIL Horizontal Position Left Hand Air Discharge Top View Front View 3 4 19 End Vie...

Page 4: ...AIR HANDLER UNIT The ACBX32CM air handler unit consists of two sections which are shipped assembled from the factory If necessary the unit may be disassembled to facilitate setting the unit Follow the...

Page 5: ...opening is fully open and free of any debris Also check to make sure that no debris has fallen into the drain pan during installa tion that may plug up the drain opening 3 Rotate the drain pan 180 fro...

Page 6: ...to downflow ACBX32CM unit circuit breakers must be rotated 180 to the UP position See AECB29 installation instructions for more details NOTE If downflow application is required order Allied downflow k...

Page 7: ...ed refrigerant lines see the piping section of the Allied Commercial Refrigerant Piping Design and Fabrication Guidelines Corp 0912 L5 AIR HANDLER UNIT SUCTION LINE LIQUID LINE Figure 8 Brazing Connec...

Page 8: ...sate Drain Before connecting drain line s check drain hole s to verify that drain opening is fully open and free of any debris Also check to make sure that no debris has fallen into the drain pan duri...

Page 9: ...Insert new filter 4 Replace panel See table 2 for replacement filter sizes Table 2 Filter Dimension Unit Model No Filter Size Inches mm 136 20 x 22 508 x 559 148and 160 20 x 24 508 x 610 Making Electr...

Page 10: ...Electric Heat W1 O Y1 R L T R L T SERVICE LIGHT THERMISTOR Y2 Y2 2ND STAGE COMPRESSOR 1 2 3 4 5 6 COMMON ELECTRIC HEAT REVERSING VALVE COMPRESSOR POWER 1 4 7 3 6 9 LINE VOLTAGE FIELD INSTALLED CLASS...

Page 11: ...ED ONLY ON SOME THERMOSTATS Y2 USED ONLY WHEN TWO SPEED COMPRESSOR IS USED HP21 AMBIENT COMPENSATING THERMISTOR CONNECTION USED ONLY ON SOME THERMOSTATS LINE VOLTAGE FIELD INSTALLED CLASS 2 VOLTAGE FI...

Page 12: ...Page 12 506316 01 11 16 Figure 15 Typical Wiring Diagram Single Phase...

Page 13: ...ation or field provided material e g Armaflex Permagum or equivalent Any of the previously mention materials may be used to seal around the main and auxiliary drains and around open areas of electrica...

Page 14: ...1055 495 230 1190 560 280 1475 695 455 25 60 1060 500 220 1185 560 275 1450 685 440 30 75 1050 495 215 1175 555 375 1415 670 430 40 100 1005 475 290 1135 535 325 1335 630 400 50 125 915 430 255 1060...

Page 15: ...5 515 1870 880 590 15 35 1750 825 510 1850 875 585 20 50 1720 815 500 1825 860 575 25 60 1685 795 490 1790 845 560 30 75 1645 775 480 1745 825 545 40 100 1530 720 450 1625 765 505 50 125 1380 650 420...

Page 16: ...inside surface temperature of the cabinet The temperature humidity difference between the inside and outside of the cabinet can cause condensation on the inside or outside of the cabinet which leads t...

Reviews: