background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Fuel                     

Type

Inlet Pressure

Manifold Pressure

Desired Minimum Maximum

On Hi 

Fire

On Lo 

Fire

Natural

Gas

7" WC

5" WC

10.5" WC

3.5" WC 1.7" WC

LP Gas

11" WC 10.5" WC

13" WC

10" WC

5.4” WC

The Ravelle™ 30 gas fireplace must be connected to the gas line in ac-
cordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 
(In Canada, the current CAN/CSA  B149.1 installation code).  The gas 
line should enter the fireplace on the left side through the hole provided 
(see diagrams on 

Page 7)

. The fireplace comes with a flex line attached 

to the supply side of the gas valve. The fitting on the end of the flex line 
can receive a 1/2” female iron pipe coupling, a 3/8” male iron pipe, or a 
shut-off valve. There is sufficient room to locate the shut-off valve under 
the firebox at the end of this flex line; however, local codes may require 
the shut-off to be located on the exterior of the fireplace. After connect-
ing the gas line, all joints in the line and connections at the valve should 
be checked for leaks before final positioning of the unit. Conduct a gas 
leakage test of the appliance piping and control system downstream of 
the shutoff valve in the supply line to the appliance.

Gas Pressure Requirements

A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLI-

ANCES IS IMPROPER GAS PRESSURE!

The most important item to check during the initial installation 

and the first thing to check when operating problems occur is 

gas pressure! 

This  fireplace  will  not  function  properly  unless  the  required 

gas pressure is supplied. See the table on this page for gas 

pressure requirements.

Two pressure taps are provided on the fireplace’s valve to check gas 
pressures. The taps are located to the right of the on/off/pilot knob (see 

Figure 29)

. The bottom tap is the inlet (supply) pressure side. To check 

inlet pressure (with the fireplace burning) insert a small phillips screwdriver 
into the tap and turn a half turn counter-clockwise. Cover the tap with the 
line from a manometer and check the pressure. Close the tap gently but 
securely after completing the check. The manifold (outlet) tap is above 
the inlet tap. To check manifold pressure (with the fireplace burning at 
the high burn setting) insert a small phillips screwdriver into the tap 
and turn a half turn counter-clockwise. Cover the tap with the line from 
the manometer and check the pressure. Again close the tap gently but 
securely after completing the check. Check the taps for gas leaks with a 
gas leak test solution - retighten if necessary.

LP and Natural Gas Supplies

Your Ravelle 30 gas fireplace is equipped from the factory for use with 
natural gas only as specified on the Safety / Listing label attached to the 
appliance. This appliance can only be operated using propane gas (LP) 
if a certified fuel conversion kit provided by Lennox Hearth Products is 
installed by a qualified service technician.  

Also check the orifice size on the label on the igniter bracket. It must be 
the correct size for the fuel and altitude.

Do not run propane tank dry.  Running the tank dry may cause 

a hazardous condition due to pressure drop in empty tank. 

Solid fuel is NOT to be used with this unit.

Robertshaw Millivolt Gas Valve

TP/TH

TH

TP

Inlet (Supply) 

Pressure Tap

Figure 29

The Manifold

(Outlet) Tap

If the pressure is not sufficient, make sure the gas supply line is large 
enough, the supply regulator is properly adjusted and the total gas load 
for the residence does not exceed the amount supplied.

Note:  The appliance and its individual shut-off valve must be disconnected 
from the gas supply piping system during any pressure testing of that 
system at test pressures in excess of 1/2 psig. The appliance must be 
isolated  from  the  gas  supply  piping  system  by  closing  its  individual 
manual shut-off valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig. Check with your 
gas supplier or plumber.

GAS LINE INSTALLATION

Summary of Contents for RAVELLE 30

Page 1: ...debiensuivrelesinstruc tionsdonn esdanscettenoticepourr duireauminimum le risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort These appliances may be install...

Page 2: ...any make shift compromises during in stallation Any modification or alteration may result in damage to the appliance or dwelling and will void the warranty certification and listings of this unit Fail...

Page 3: ...12 Vent Considerations 13 Horizontal Vent Installation 14 Vertical Vent Installation 14 Vertical Vent Termination Clearances 15 Flue Restrictors 16 Horizontal Terminations 17 Vertical Terminations 17...

Page 4: ...rd for Mobile Home Installations ANSI A225 1 latest edition Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a c...

Page 5: ...g the cassette valve and pilot assembly or installing a conversion kit Only Lennox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG Contact your Lennox Hearth Products...

Page 6: ...offs 0 0mm Rear corners to enclosure from standoffs 0 0mm Top to header from standoffs 0 0mm Bottom of unit to floor 0 0mm Edge of door glass to side wall and side trim 6 1 4 159mm Back to enclosure f...

Page 7: ...ical power supply wiring should be routed to the right rear of the unit Note The fireplace may be placed directly on wood or non combustible flooring but not on vinyl floor covering or carpet Framing...

Page 8: ...d if desired Should a hearth extension thicker than 7 8 22 mm be desired the height of the fireplace must be raised the thickness of that hearth extension less the 7 8 22 mm For example if a 2 7 8 73...

Page 9: ...behind the fireplace see below Cement Board 3 8 Tile and 1 2 Cement Board Behind Fireplace Face Cement Board a minimum of five inches wide Sheetrock 1 Reveal 5 127mm Minimum Sheetrock Facing Installat...

Page 10: ...d face installation The corners of the 1 25mm reveal around the fireplace opening need to be adjusted prior to installing an arched face see below Remove screws A and loosen screw B Rotate the corner...

Page 11: ...efore installing the fire place face The acid wash will tarnish the face Consult your masonry installer Face Installation AnumberofdifferentfacesareavailablefortheRavelle 30gasfireplace however all th...

Page 12: ...t approved or manufactured by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions Vent Parts List DirectventpipeSecurity...

Page 13: ...ed by examining the inside of the female ends Supports Horizontal runs of vent must be supported every three feet Wall straps are available for this purpose Pipe Sealing If Security Secure Vent pipe i...

Page 14: ...6 mm rise for every one foot of run towards the termination 7 If the wall being penetrated is constructed of non combustible mate rial such as masonry block or concrete a 7 1 2 191 mm diameter hole is...

Page 15: ...m is 10 feet 3M Vertical Vent Termination Clearances The vent air intake termination clearances above the high side of an angled roof is as shown in the Figure 17 Termination Heights For Vents Above F...

Page 16: ...sitions are based on tests run in a laboratory The optimum restrictor positions may need to be adjusted slightly depending on the conditions surrounding the residential installation Do not adjust rest...

Page 17: ...the top of the vertical length of pipe is allowed as long as the overall length of the horizontal run of pipe does not exceed those shown below Use the restrictor positions indicated Horizontal Termi...

Page 18: ...ve meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service...

Page 19: ...k panels which are shipped in the firebox 2 The long rectangular panel goes in the rear of the firebox he thin layer of bricks should be down The panel rests on 3 metal tabs protruding from the rear o...

Page 20: ...and join this wire to the black supply wire reusing the wire nut Repeat for white wire Reinstall the electrical box cover If a wall mounted burner on off switch or thermostat is to be used the wires r...

Page 21: ...insertasmallphillipsscrewdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from a manometer and check the pressure Close the tap gently but securely after completi...

Page 22: ...ing with or without the fireplace fan running air is drawn from a distant room lowering the pressure in that room through the return air duct into the bottom of the fireplace The air then passes throu...

Page 23: ...appliance is equipped with a piezo ignition device to light the pilot When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell around the appliance area for gas Be sure to sme...

Page 24: ...r switch and or thermostat if in stalled to its lowest setting 2 Turn off electric power to the appliance if service is to be performed 3 Push in gas control knob slightly and turn clockwise to OFF Do...

Page 25: ...ellow Flame Blue Flame Center Ports on Burner Assembly Burner Flame Appearance Figure 34 Air Shutter Control Lever Gas Valve Air Shutter Adjustment The Ravelle 30 gas fireplace has an air shutter cont...

Page 26: ...cur Do not mount the thermostat where it may be affected by Radiant heat from this appliance fireplaces sun or other heat sources Drafts or dead spots behind doors or in corners Hot or cold air from d...

Page 27: ...the chance of the burner not igniting Follow the instructions included with the thermostat for wiring The ther mostatandrockerswitchwillturntheburneronandoffindependently Be suretosettherockerswitcht...

Page 28: ...s when the unit is hot o Check the hot air outlet vents for lint or other accumulations Never block or restrict vent openings obstruct flow of ventilation air or use vents other than those approved fo...

Page 29: ...and Log Set Installation 3 Remove the two allen head screws at the left and right rear of the firebox securing the air control panel Lift out the air control panel 4 Remove the one allen head screw h...

Page 30: ...ht pilot If pilot lights turn off pilot and trigger the igniter again If pilot lights an intermittent gas air supply may be the problem if longer purge will not light check gap between electrode and p...

Page 31: ...Main Burner Orifice 52 LP H5958 Pilot Orifice NG H3141 Pilot Orifice LP H5897 Main Gas Valve Supply Line H3117 Blower W Mounting Bracket H3857 Blower Snap Switch H5742 Blower Speed Control rheostat H...

Page 32: ...S Glass Door Box 1 of 3 75092 PILCST PILRS2 Back Pillars Top Box 2 of 3 75094 PILCST GRL TRD3 Grill Bars Traditional Box 3 of 3 or 75091 PILCST GRL FIL3 Grill Filigree Ornate Box 3 of 3 Gas Conversion...

Page 33: ...a Black Nickel 75298 AI30 TUSCAN BLK Tuscan Black 75300 AI30 TUSCAN GOLD Tuscan Gold 75299 AI30 TUSCAN BRNKL Tuscan Brushed Nickel 75301 AI30 TUSCAN BKNKL Tuscan Black Nickel Insets Required Includes...

Page 34: ...VEC DU COMBUSTIBLE SOLIDE TEST SELON LA NORME ANSI Z21 88 2005 CSA 2 33 2005 FOYER RADIANT AU GAZ UL307B CSA P 4 1 02 ET CGA 2 17 M91 CET APPAREIL DOIT TRE INSTALL CONFORM MENT AUX EXIGENCES DES CODES...

Page 35: ...ssistance ou information suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d...

Page 36: ...erage Retain this manual File it with your other documents for future refer ence Product reference information We recommend that you record the following important information aboutyourappliance Pleas...