Lennox Hearth Products MPD35PF-NE-B Installation Instructions Manual Download Page 4

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Test gauge connections are provided on the 

front of the millivolt and electronic gas control 

valve (identified IN for the inlet and OUT for the 

manifold side).  The control valves have a 3/8" 

(10mm) NPT thread inlet and outlet side of the 

valve (refer to 

Figures 1 and 2

).

Propane tanks are at pressures that will cause 

damage to valve components.  Verify that the 

tanks have step down regulators to reduce the 

pressure to safe levels.

Gas Valve Diagrams

See 

Figure 1

 for Millivolt models and 

Figure 2 

For Electronic Models.

These appliances must not be connected to a 

chimney or flue serving a separate solid fuel 

burning appliance.

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(0.55 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

These appliances must be isolated from the 

gas supply piping system (by closing their 

individual manual shut-off valve) during any 

pressure  testing  of  the  gas  supply  piping 

system  at  test  pressures  equal  to  or 

less 

than

 1/2 psig (3.5 kPa).

These appliances and their individual shut-off 

valves must be disconnected from the gas 

supply piping system during any pressure 

testing of that system at pressures 

greater 

than

 1/2 psig (3.5 kPa).

Orifice Sizes -  Sea Level to High Altitude

(All Models)

These appliances are tested and approved for 

installation at elevations of 0-4500 feet (0-1372 

meters) above sea level using the standard burner 

orifice sizes (marked with an "*" in 

Table 4 

).  

For elevations above 4500 feet, contact your gas 

supplier or qualified service technician. 

Deration -

 At higher elevations, the amount of 

BTU fuel value delivered must be reduced by 

either using gas that has been derated by the gas 

company or by changing the burner orifice to a 

smaller size as regulated by the local authorities 

having jurisdiction and by the (USA) National 

Fuel Gas Code NFPA 54/ANSI Z223.1 - latest 

edition  or,  in  Canada,  the  CAN/CSA-B149.1 

codes - latest edition.

Install the appliance according to the regulations 

of the local authorities having jurisdiction and, 

in the USA, the National Fuel Gas Code NFPA 

54 / ANSI Z223.1 - latest edition or, in Canada, 

the CAN/CSA-B149.1 - latest edition.

Flame breadth, height and width will dimenish 

4% for every 1,000 feet of altitude.

REQUIREMENTS  FOR  THE  COMMON-

WEALTH OF MASSACHUSETTS

These fireplaces are approved for installation in 

the US state of Massachusetts if the following 

additional requirements are met:

•  Install  this  appliance  in  accordance  with 

Massachusetts Rules and Regulations 248 

C.M.R. 

•  Installation and repair must be done by a 

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

•  The flexible gas line connector used shall 

not exceed 36 inches (92 centimeters) in 

length.

•  The individual manual shut-off must be a 

T-handle type valve.

Massachusetts Horizontal Vent Requirements 

In the Commonwealth of Massachusetts, hori-

zontal terminations installed less than seven 

(7) feet above the finished grade must comply 

with the following additional requirements:

•  A  hard  wired  carbon  monoxide  detector 

with an alarm and battery back-up must be 

installed  on  the  floor  level  where  the  gas 

fireplace is installed.  The carbon monoxide 

detector must comply with NFPA 720, be 

ANSI/UL 2034 listed and be ISA certified.

•  A metal or plastic identification plate must 

be permanently mounted to the exterior of 

the building at a minimum height of eight (8) 

feet above grade and be directly in line with 

the horizontal termination.  The sign must 

read, in print size no less than one-half (1/2) 

inch in size, GAS VENT DIRECTLY BELOW.  

KEEP CLEAR OF ALL OBSTRUCTIONS.

NEW YORK CITY, NEW YORK (MEA)

Installation  of  these  fireplaces  are  approved 

for installation in New York City in the US state 

of New York.

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

4.5" WC

(1.12 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 2

Gas Pressure - All Models

Tables 2 and 3

 

show the appliances' inlet and 

manifold gas pressure requirements:

Figure 2

Honeywell Electronic

 Gas Valve

ON/OFF Switch

Electronic

Gas Control

Valve

Inlet

Pressure

Port

Manifold Pressure Port

OFF

IN

P

S

I

ON

CONTROL

IG

N

IT

ER

H I

LO

W

HT

PT

HT

PT

PILO

T

PI

LO

T

ON

it

OFF

IN

OUT

HI/LO Variable

Flame Height

Adjustment

Figure 1 - 

SIT Millivolt  Gas Valve

Manifold Pressure Tap

Inlet Pressure Tap

Pilot Adjustment

Screw

Main Gas Control Knob

OFF/PILOT/ON

Burner Orifice Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#37 (0.104") 

*

24M10 •

1.55 mm (0.061")

*

42M79 •

Table 4           

* Standard size installed at factory

                                        •  Part /Cat. Number

Summary of Contents for MPD35PF-NE-B

Page 1: ...imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l e...

Page 2: ...of high surface temperature and should stay away to avoid burns or clothing ignition Lesenfantsetlesadultesdevraient treinfor m sdesdangersqueposentlestemp ratures de surface lev es et se tenir dista...

Page 3: ...an cause serious injury or death from fire burns explosion or carbon monoxide poisoning Onlytrimkit s suppliedbythemanufacturer shall be used in the installation of this ap pliance Seules les trousses...

Page 4: ...d width will dimenish 4 for every 1 000 feet of altitude REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS Thesefireplacesareapprovedforinstallationin the US state of Massachusetts if the following...

Page 5: ...ED HOME REQUIREMENTS This appliance may be installed in an aftermar ket permanently located manufactured home and must be installed in accordance with the manufacturer s instructions and the Manufac t...

Page 6: ...ent Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figures 4 and 5 Note See Figure 36 on Page 21 for the exterior wall recess allowances of...

Page 7: ...s n i h c a e o t e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b...

Page 8: ...the unit The appliance may be located onornearconventionalconstructionmaterials However if installed on combustible materials such as carpeting vinyl tile etc a metal or woodbarriercoveringtheentireb...

Page 9: ...and pre wired 1 Remove the shipping carton Remove the shipping pad exposing the front glass door 2 Open the two latches located under the firebox floor securing the glass door Remove the door by tilt...

Page 10: ...The typical sequence of installation is outlined below However each installation is unique and may result in variations to the steps described See the page numbers references in the follow ing steps f...

Page 11: ...hed dimension should be 22 558 mm Inches millimeters Minimum Framing Stud Size is 2 x 4 See side views of fireplace below for gas line inlet location options Fireplace Framing Specifications Center of...

Page 12: ...aming Specifications Center of gas line is 3 1 8 inches 79 mm up from floor Notes This dimension does not include the addition of drywall to the inside of framing or clearance for the Side Vent Seal C...

Page 13: ...supplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certainlyno one unfamiliar and unqualified should attempt sizing or ins...

Page 14: ...openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with this appliance The restrictor is installed in the appliance t...

Page 15: ...9 2 2 5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8...

Page 16: ...age 15 for an aidinselectinglengthcombinations Elbowsare available in 90 and 45 configurations Refer to Figure 24 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telesc...

Page 17: ...n of the venting system every 8 feet 2 4m above the fireplace vent outlet One method of support is by utiliz ing field provided support straps conventional plumber s tape Secure the plumber s tape to...

Page 18: ...WO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uCeilin...

Page 19: ...x use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H1 Maximum V Minimum feet meter feet meter 5 1 524 Elbow Only 5...

Page 20: ...ocking any of the previously connected vent sections See Figure 24 on page 15 I Continueinstallationofhorizontal inclined sections Continue with the installation of the straightventsectionsinhorizonta...

Page 21: ...ll thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacerovertheopeningattheexterior sideoftheframing...

Page 22: ...4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall Note Secure Vent components rigid vent pipe and terminal are shown in the figures...

Page 23: ...revery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum feet meter feet meter 3 0 914 Elbow Only 5 1 524 1 0 3...

Page 24: ...restop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent THREE 90 DEGREE ELBOWS Square termination SV4 5HT 2 shown Square...

Page 25: ...adapter overthepreviouslyinstalledsectionorappliance collar adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four incline channels of the...

Page 26: ...ent une fois l entretien termin CAUTION Donotconnectoptinalcontrolswitch to 120VAC power supply 2 Install the junction box and receptacle outlet to the left of the valve in the front for optional blow...

Page 27: ...ompliance with local codes A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas...

Page 28: ...ight until it disengages from the left corner post hole Remove the modesty panel To remove the modesty panel slide the panel forward until it contacts the cabinet bottom panel then lift straight up an...

Page 29: ...ance beforeyouinstallvermiculite embersandlogs DO NOT attempt to install the logs until the ap plianceinstallationhasbeencompleted thegas lineconnectedandtestedforleaksandtheinitial burner operation h...

Page 30: ...wool Separate into Quarter Size separate Pieces NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE F D Bottom View of Logs in packaging C E A B C F A D Top View of Logs E B Top View of Logs Installed F E A...

Page 31: ...in Figure 58 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material Note This appliance is provided with enough Glowing Embers for several applicati...

Page 32: ...sarecool Turnoffallelectricitytotheappliance beforeyouinstallgrate volcanicstone vermiculite embers and logs This appliance is not designed to burn wood Any attempt to do so could cause irreparable da...

Page 33: ...e Panel see Figure 62 Retrieve the glass door Visually inspect the gasket on the backside of the frame Gasket surface must be clean free of irregularities and seated firmly Position the door in front...

Page 34: ...shown in the table in Figure 64 2 Light appliance follow lighting procedure on lighting label in control compartment or see the Care and Operation Manual 3 Allow the burner to operate for at least 15...

Page 35: ...Burner Factory Air Shutter Opening Setting All Models Model Natural Gas Propane Gas MPD35ST PF 1 8 3 2mm 1 4 6 4mm Air Shutter Adjusting Rod Increase Shutter Opening In This Direction Decrease Shutter...

Page 36: ...errupteur ou le thermostat mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou d...

Page 37: ...1 SV4 5SC6 Storm Collar 6 per box H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Firestop Spacer 5 flex H2246 SV4 5HF 10 Firestop Spacer Horizon tal rigid 3 1 1 spacing 10 Pack H2247 SV4 5VF 10...

Page 38: ...HGS Termination Guard for Horizontal Square Termi nation Deluxe 1 pack Ref instr 750 055M H5820 SV4 5HTSK Termination Shroud Guard for Horizontal Square Termination 1 pack ref instr 750246M H5816 750...

Page 39: ...cabinet panel hole Pull the panel away from the fireplace See Figure 52 on Page 29 WARNING Thisconversionkitshallbeinstalledbyaqualifiedserviceagencyinaccor dance with the manufacturer s instructions...

Page 40: ...t gas line to free the pilot assembly from the gas line Remove the pilot orifice and replace it with the one provided with the conversion kit Reinstall the pilot assembly by reversing the steps detail...

Page 41: ...on kit to the rating plate on the appliance Step 11 Turn on gas supply and test for gas leaks b Install the burner as shown in Figure 72 Ensure that the arm of the venturi of the burner is hooked onto...

Page 42: ...42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...