CHIMNEY - PARTS AND COMPONENTS LISTS

Secure Temp GX - 2” Insulated Galvanized Chimney System 

(Recommended Insulated System)

Galvanized

 

(7” ID & 11” OD) U.S.A. ONLY

Description

Cat./Part No.

Lengths & Misc. Chimney Components 

Length 8”, 7GXL8

7GXL8

Length 12”, 7GXL12

7GXL12

Length 18”, 7GXL18

7GXL18

Length 24”, 7GXL24

7GXL24

Length 24” (stainless steel exterior fl ue), 7XL24

7XL24

Length 36”, 7GXL36

7GXL36

Length 36” (stainless steel exterior fl ue), 7XL36

7XL36

Length 48”, 7GXL48

7GXL48

Length 48” (stainless steel exterior fl ue), 7XL48

7XL48

15º Elbow, 7GXE15

7GXE15

30º Elbow, 7GXE30

7GXE30

Rain Termination Cap, 7CC (stainless steel)

7CC

Wall Band, XBM

XBM

Supports

Offset Support, XSO

XSO

Roof / Floor support, XST

XST

Roof Brace, XBS2

XBS2

Roof Flashings

Roof Flashing, Flat (includes spacer & collar), 7XF

7XF

Roof Flashing, Adjustable (5º to 30º) (includes spacer 
& collar), 7XFA

7XFA

Roof Flashing, Adjustable (30º to 45º) (includes spacer 
& collar), 7XFB

7XFB

Storm Collar (spacer included), 7XFC

7XFC

Firestops & Braces

Firestop, 7XBF

7XBF

Radiation shield, 7XRS

7XRS

Insulated attic radiation shield, 7XRSA

7XRSA

30º Insulated wall radiation shield, 7XRSMI30

7XRSMI30

Wall Band, XBM

XBM

Installation Accessories

Description

Cat./Part No.

Facades

 (Required - Order Separately)

Montecito Estate™

 

Facade Black, MEFBK

H4850

Montecito Estate

 

Facade Brushed Nickel, MEFBN

H4851

Montecito Estate

 

Facade Hammered Steel, MEFMC

H4852

Doors - 

(Required - Order Separately)

Montecito Estate

 

Doors Black, MECBK

H4853

Montecito Estate

 

Doors Brushed Nickel, MECBN

H4854

Montecito Estate

 

Doors Hammered Steel, MECMC

H4855

Outside Air Kit

 

(included with fi replace)

Outside Air Coupler To Connect Outside Air (UZI) To Fireplace, 
UZIAD

UZIAD

Outside Air Ducting - includes 4” insulated fl ex x 10’ long, UZI

UZI

Gravity Kit

Gravity kit: 

Complete double duct system includes: 2 elbows 90º, 

2 telescopic lengths, 2 grill supports & 2 black grills, 2 fi replace 
adaptors. 

7B30ZK-1

Gravity Kit Accessories

Black Grill With Support (set of 2) , 7B30ZO

7B30ZO

Brass Grill (for 7B30ZK-1) (set of 2), 7B30ZGB

7B30ZGB

Elbow 90º, 8” dia. I.D., 7B26ZE90

7B26ZE90

Elbow 45º, 8” dia. I.D., 7B26ZE45

7B26ZE45

Telescopic length, 8” dia. I.D. (15” to 26”), 7B26ZLA

7B26ZLA

Adjustable length, 8” dia. I.D. (2” - 5”), 7B26ZL2A

7B26ZL2A

Length fi ve (5) feet, 8KL5

8KL5

Length four (4) feet, 8KL4

8KL4

Length three (3) feet, 8KL3

8KL3

Length two (2) feet, 8KL2

8KL2

Length one (1) feet, 8KL1

8KL1

Fireplace Kits 

Rigid fi rescreen, BTZN

BTZN

Masonry Chimney Adaptor, 30º, BISTMA30
(for use with TUBINOX liner)

BISTMA30

OPTIONAL INSTALLATION ACCESSORIES

Fireplace Model MONTEST - Approved Venting Components  manu-
factured by Security Chimneys International only.

•   

7” diameter chimney - 

ACBI (air cooled), Secure Temp™  GX (U.S. 

only) and Secure Temp S-2100+ (or Nova Temp ).

•  

7” diameter chimney for relining masonry chimneys

 - TUBINOX 

chimney (or PROJET SS), 7” diameter with adaptor for installation 
in a masonry chimney.

Notes:

Nova Temp™  

 

is equivalent to S-2100+

2

 Chimney Adaptor (S-2100+ / ) for CANADA ONLY -  If you want to 

install a S-2100+ / chimney, an adaptor is available (6UCA).

ACBI Chimney is NOT recommended at elevations above 4,000   or in cold 
climates (climates where temperatures will fall below 32° F / 0° C).  With the 
ACBI chimney, you must use a starter section before installing the fi rst chimney 
length (ACBI7SB or ACBI7SB30).

20

Summary of Contents for MONTECITO ESTATE MONTEST

Page 1: ...e la demande Num ro de la pi ce 850 038CF INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards ULC S610 UL 127 Report No 304 7213 EPA Cert No 609...

Page 2: ...e left partly opened smoke may be drawn into the room Use optional firescreen when doors are fully opened WARNING Usecarewhenselectingwindow treatments for windows located near the fireplace Avoid usi...

Page 3: ...PARTS REQUIRED Fireplace model MONTEST 7 diameterchimney Model SecureTemp S 2100 Nova Temp HT6000 Secure TempGX U S only or ACBI manufactured by Security Chimneys International only including Chimney...

Page 4: ...burnveryintenselyus ing this method and may damage the firebox Medium Combustion This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposi...

Page 5: ...e will be between 6 8 hours and at this combustion rate the level of BTU s is at its lowest Building a Fire A To start a fire place several crumpled up ballsofnewspaperinthefirebox Placesmall dry piec...

Page 6: ...e chimney WARNING When cleaning the fireplace the ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on t...

Page 7: ...1 400 F If the glass breaks or cracks it must be replaced with an identical ceramic glass Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate Replacement...

Page 8: ...A Frame the fireplace using 2 x 3 or heavier lumber B WARNING Combustible materials cannot be used in the space directly above the fireplace except for the studs above the fa cade that support the fa...

Page 9: ...8 1686 mm Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wall at the fi...

Page 10: ...It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circuit byaqualifiedelectrician Forconnection usethe electrical box supplied wit...

Page 11: ...eat A furnace duct is only single wall and not double wall as is required for the Montecito Estate hot air exhaust 7 Use only Security Chimneys International grills and components as described in this...

Page 12: ...above or below floor level Makea4 1 4 110mm holeintheoutsidewallofthehouseatthechosen location From outside place the outside air register in the hole open side down and fasten the register to the wal...

Page 13: ...are located on lower floors in the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The fireplace model MONTEST may be installed only with Se...

Page 14: ...rsal support AC10SU 4 Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch see Figures 25 26 For sloping roofs place the flashing under the upper shin...

Page 15: ...ns on Page 14 5 From below install a firestop See Figure 23a 6 A support XST or XSO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney 1 Install the first e...

Page 16: ...mm 45 21 32 1160 mm 54 1 8 1375 mm B 17 9 16 446 mm 20 7 16 519 mm 24 5 8 625 mm 28 7 8 733mm 37 3 8 949 mm 42 1067 mm 44 3 4 1137 mm 49 1245 mm 59 9 32 1353 mm 61 3 4 1568 mm Chimney Elbow Offset Hei...

Page 17: ...diation Shield Framing 2 x 3 Figure 29 Roof Support Note In cold areas it is recommended to protect the chimney in a insulated chase Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET...

Page 18: ...t of supported chimney NOTE For the ACBI chimney a support section ACBI7SL must be used every 30 feet 9m or an universal support every 20 feet 6m instead of the universal roof support ST CHIMNEY MAXIM...

Page 19: ...will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 TUBINOX liner elbow can be easily slipped through 4 Slid...

Page 20: ...ECMC H4855 Outside Air Kit included with fireplace Outside Air Coupler To Connect Outside Air UZI To Fireplace UZIAD UZIAD Outside Air Ducting includes 4 insulated flex x 10 long UZI UZI Gravity Kit G...

Page 21: ...ashing Adjustable 30 45 includes spacer collar ACBI7FBR H3277 Misc Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RS...

Page 22: ...PR SR2417 Right Side Refractory Bricks Front PR SR2419 Left Side Refractory Bricks Back PR SR2416 Left Side Refractory Bricks Front PR SR2418 Bottom Refractory Brick PR SR2422 Wooden Door Handle PR SR...

Page 23: ...NOTES 23...

Page 24: ...ction which were not manufactured or supplied by LHP or for the labor necessary to install repair or remove such materials parts or construction All replacement or repair components will be shipped F...