ACCESSORY COMPONENTS

The following items are available for use with 
this appliance.

Cat. No.  Model 

Description

H3430  GEP-33BL  Glass Enclosure Panel, Black on Bronze
H3433  GEP-33PB  Glass Enclosure Panel, Brass on Bronze
H3434  GEP-33BS  Glass Enclosure Panel, Stainless on Bronze

Cat. No.  Model 

Description

H3435 TK3-33BL 3-pc. Black Trim Kit, MPE-33R
H3436 TK3-33PB 3-pc. Brass Trim Kit, MPE-33R
H1932 TK3-33BS 3-pc. Stainless Trim Kit, MPE-33R

Cat. No.  Model 

Description

85L87 

FWSK 

Wall Switch Kit, White             

   

Wall Thermostat

The wall thermostat kit provides temperature 
control for optimum comfort.

Cat. No.  Model 

Description

89L36   

WTK 

Wall Thermostat Kit

Wall Switch Kit

Trim Kit

Glass Enclosure Kit

This kit contains trim panels used to fi nish the 
gaps between the wallboard or optional mantel 
and the fi replace, providing the appliance a 
fi nished built-in look. 

Cat. No.  Model 

Description

H1645 

PCK 

Power Cord Kit, 3-Prong, 110V

Power Cord Kit, 3-Prong, 110V

~83”

If a power cord is preferred instead of hard-
wiring the power supply to the fi replace, this 
optional power cord kit is available (110 Volt 
installations only).

    

  

These glass enclosure panels are a one-piece 
panel, which have a bi-fold “look” as shown 
below.

Cat. No.  Model 

Description

H3604  FFEP-33M  33" Decorative Complete Front Face, Mission Style
H3605  FFEP-33IA  33" Decorative Complete Front Face, Interlocking Arch

Summary of Contents for LENNOX MPE-33R

Page 1: ...could result in an unsafe and potentially dangerous installation IMPORTANT IFOPTIONALGLASSDOORSAREPURCHASED TO ASSURE PROPER ALIGNMENT INSTALL THIS FIREPLACE IN A SQUAREANDPLUMBCONDITION USINGSHIMSAS...

Page 2: ...PERFORMEDBYAQUALIFIED SERVICE TECHNICIAN UNDER NO CIRCUMSTANCES SHOULD THIS FIREPLACE BE MODIFIED PARTS HAVINGTOBEREMOVEDFORSERVICING MUST BE REPLACED PRIOR TO OPERAT ING THE FIREPLACE AGAIN TABLE OF...

Page 3: ...hermostat Kits optional kits see Page 17 Low voltage wire is provided for the wall switch connection The wires gage requirements are shown on Table 1 DO NOT USE THIS APPLIANCE OUT DOORS DO NOT EXPOSE...

Page 4: ...Side Electrical Access 13 3 4 350 mm 5 1 4 134 mm 24 1 2 622mm 27 1 2 700mm 21 1 8 537 mm FIREPLACE SPECIFICATIONS Front View Side View 36 1 4 921 mm 25 5 8 35 1 4 651 mm 895 mm 51 1 4 1302 mm 32 812...

Page 5: ...ge 120 V 15 Amps or 240 V 20 Amps A dedicatedcircuitisrequiredtopreventover loading a house circuit in cases of having multiple appliances on the same circuit Use an outlet that is protected by a grou...

Page 6: ...ame Ember On Off front most switch Figure 5 On On On Off Off Off When using the main power on off switchinsidethebody thepoweron off switch outside the body optional wall switch kit must be in the OFF...

Page 7: ...en press the display button B to activate the lights Note If the flame does not come on immedi ately adjust brightness and intensity buttons E K 4 Toincreasethebrightness pressandrelease the light bri...

Page 8: ...ure the mounting plate Remove the 4 side screws first 2 on each side Remove the middle screw that is on the top of the handle last b Slowlylowertheheater blowerassembly and let it rest on the 2 suppor...

Page 9: ...item 7 on Page 17 Remove Grate 5 Lift out log ember assembly by tilting for ward and firmly pulling on back of ember bed assembly It should pop out from track and lift out Caution Be careful not to sc...

Page 10: ...ations on Page 3 P P TRA N LIGHT POWER N N FAN N M SIP13 SIP11 SIP7 T P Transformer Control Panel Flame Ember On Off Switch SIP3 SIP2 SIP4 TEM SIP6 K H K P REMOTE N FLAME L FLAME Circuit Board Remote...

Page 11: ...me Ember On Off Switch Control Panel Heater On Off Switch Wall Switch power on off MAIN POWER L1 L1 L2 L2 N1 N2 N N Control Panel power on off Outside Switches Transformer Remote Sensor Temperature Se...

Page 12: ...RAMS optional kits see Page 18 When using the main power on off switch inside the body the power on off switch outside the body optional wall switch kit must be in the OFF position When using power on...

Page 13: ...ostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the the black and white wires...

Page 14: ...witch per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the 2 red wires and pull out t...

Page 15: ...ulb s burnt out or wiring is loose Homeowner Inspect all wiring for loose connections and repair or replace if necessary Inspect light bulbs and replace if necessary 4 Flame sputters Flame motor is de...

Page 16: ...Panel Assembly H1630 1 9 Flame Cylinder Assembly H1631 1 10 Flame Motor H1632 1 11 Lennox Logo Kit 1 Each 12L15 1 12 Log Assembly And Ember Bed H1945 1 13 Panel Bottom Front H1946 1 14 Panel Flame Cov...

Page 17: ...NOT TO SCALE 17 REPLACEMENT PARTS COMPONENT DIAGRAMS 17 14 16 11 1 4 2 5 6 6 7 8 12 13 15 19 3 20 1 9 Front View 18 POWER ON OFF DISPLAY ON OFF Dimmer Brighter EMBERS HEATER ON OFF TEMP CONTROL HIGH M...

Page 18: ...control for optimum comfort Cat No Model Description 89L36 WTK Wall Thermostat Kit Wall Switch Kit Trim Kit Glass Enclosure Kit This kit contains trim panels used to finish the gaps between the wallbo...

Page 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19 NOTE THIS PAGE LEFT BLANK INTENTIONALLY...

Page 20: ...0 032M REV A 02 2006 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult...