LNL-1320-2RP Dual Door Control Module
102 —
revision 7
AC Door Strike Wiring using Internal Relay
DC Door Strike Wiring
Suppression diode selection:
-
Diode current rating:
>1x strike current
-
Diode breakdown voltage:
4x strike voltage
-
For 12 VDC or 24 VDC strike, use diode 1N4002 (100 V/1 A) typical
AC Door Strike Wiring using Internal Relay Callouts
Callout
Description
1
AC strike
2
To AC power source
3
Fuse
4
TB2 or TB4 on LNL-1320-2RP
5
Suppression MOV