DMX-3901-A Installation and Operation Manual
27
Chapter 3: Operation
Enabling or Disabling an Alarm Parameter
To enable or disable an alarm parameter, follow these steps:
1. Select
Alarms
, then select
Config
, and then press
Enter
.
2. Select one of the alarm parameters, and then press
Enter
.
3. Press
Enabled
or
Disabled
.
4. Press
Enter
to activate the selection.
Restoring Default Settings
To restore the alarms to their default settings, follow these steps:
1. Select
Alarms
, select
Config
, and then press
Enter
.
2. Scroll down the list of alarms, and then select
Reset.
3. Press
Enter
to activate the selection.
The following table lists the default alarms for the DMX-3901-A
module. You can enable or disable these settings, but you cannot change
the level of the alarm.
Table 3-3.
DMX-3901-A Default Alarms
Card-Edge
Alarm ID
Name of Alarm
Alarm
Level
Meaning
SdiPrsnt [RO] SDI Input Video
Present
Major
Loss of SDI input
de-embedding
Grp1_Err [RO] Group 1 Error Status Major
Group 1 de-embedding
error
Grp2_Err [RO] Group 2 Error Status Major
Group 2 de-embedding
error
Grp3_Err [RO] Group 3 Error Status Major
Group 3 de-embedding
error
Grp4_Err [RO] Group 4 Error Status Major
Group 4 de-embedding
error
Summary of Contents for DMX-3901-A
Page 2: ......
Page 5: ...Edition B May 2005 DMX 3901 A Audio Demultiplexer Installation and Operation Manual ...
Page 9: ...vi DMX 3901 A Installation and Operation Manual Contents ...
Page 14: ...DMX 3901 A Installation and Operation Manual xi Preface ...
Page 15: ...xii DMX 3901 A Installation and Operation Manual Preface ...
Page 57: ...42 DMX 3901 A Installation and Operation Manual Appendix A Tree View Navigation ...
Page 64: ......